Table Of Contents; Introduction; General Information; Scope Of This Manual - Daikin Altherma ERSQ014AAV1 Installation Manual

Outdoor unit for air to water heat pump
Hide thumbs Also See for Altherma ERSQ014AAV1:
Table of Contents

Advertisement

ERSQ011~016AAV1
ERSQ011~016AAY1
ERRQ011~016AAV1
ERRQ011~016AAY1
C
ONTENTS
1. Introduction................................................................................ 1
1.1.
General information........................................................................ 1
1.2.
Scope of this manual ..................................................................... 1
1.3.
2. Accessories ............................................................................... 2
3. Safety considerations ................................................................ 2
4. Installation of the unit................................................................. 3
4.1.
Selecting installation location......................................................... 3
4.2.
Precautions on installation ............................................................. 5
4.3.
Dimensions and servicing space ................................................... 6
4.4.
Inspecting, handling and unpacking the unit .................................. 6
4.5.
Drain work ...................................................................................... 7
4.6.
Installing the unit ............................................................................ 7
5.1.
Selection of piping material............................................................ 7
5.2.
Refrigerant pipe size ...................................................................... 8
5.3.
Allowable pipe length and height difference................................... 8
5.4.
Guidelines for necessity of a trap................................................... 8
6. Precautions on refrigerant piping............................................... 8
6.1.
Guidelines for brazing .................................................................... 8
6.2.
Guidelines for flare connection....................................................... 9
6.3.
Guidelines for handling stop valve ................................................. 9
7. Piping connection work............................................................ 10
7.1.
Refrigerant piping......................................................................... 10
7.2.
Preventing foreign objects from entering ..................................... 10
7.3.
Leak test and vacuum drying ....................................................... 10
7.4.
regarding insulation...................................................................... 11
8. Charging refrigerant................................................................. 12
8.1.
8.2.
Calculating the additional refrigerant charge ............................... 12
8.3.
Method for adding refrigerant....................................................... 13
9. Electrical wiring work............................................................... 13
9.1.
Precautions on electrical wiring work........................................... 13
9.2.
Internal wiring - Parts table ......................................................... 14
9.3.
System overview of field wiring .................................................... 15
9.4.
9.5.
Specifications of standard wiring components............................. 15
10.1. Pre-operation checks ................................................................... 16
11. Test operation and final check ................................................. 17
11.1. Final check ................................................................................... 17
11.2. Test run ........................................................................................ 17
12. Maintenance and servicing...................................................... 17
12.1. Service precautions ..................................................................... 17
12.2. Service mode operation ............................................................... 17
13. Disposal requirements............................................................. 19
Installation manual
1
Outdoor unit for air to water heat pump
Page
The English text is the original instruction. Other languages are
translations of the original instructions.
1. I

1.1. General information

Thank you for purchasing this unit.
The outdoor unit is the air to water Daikin ERSQ or ERRQ heat
pump.
ERRQ units include special equipment (insulation, heater sheet, ...)
to ensure good operation in areas where low ambient temperature
can occur together with high humidity conditions. In such conditions
the ERSQ models may experience problems with severe ice build up
on the aircooled coil. In case such conditions are expected, the
ERRQ must be installed instead. These models contain counter-
measures (insulation, heater sheet, ...) to prevent freeze up.
NOTE
Possible options
For ERSQ models an optional bottom plate heater kit EKBPHT16A
can be connected to the outdoor unit. Refer to the installation manual
of the bottom plate heater kit for further details.
ERRQ

1.2. Scope of this manual

This installation manual describes the procedures for unpacking,
installing and connecting all ERSQ or ERRQ outdoor unit models.
NOTE
READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY
PLACE FOR FUTURE REFERENCE.
IMPROPER
INSTALLATION
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.
IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DEALER FOR ADVICE AND
INFORMATION.
NTRODUCTION
An ERSQ or ERRQ outdoor unit can only be connected
with the EKHBRD indoor unit.
Heater sheet
ERSQ_V1 + Y1
Optional kit
ERRQ_V1 + Y1
Standard
(a) Combination of both options is prohibited.
The installation of the EKHBRD indoor unit is
described in the indoor unit installation manual.
Installation manual
OR
ATTACHMENT
OF
Drain socket
(a)
(a)
Optional kit
Use prohibited
Snow cover
EK016SNC
ERSQ+ERRQ011~016AAV1+Y1
Outdoor unit for air to water heat pump
4PW49635-1C

Hide quick links:

Advertisement

Table of Contents
loading