13. Routine check after installation

Check after installation

Items to be checked
Has it been fixed firmly?
Have you done the refrigerant leakage test?
Is heat insulation sufficient?
Does the unit drain well?
Is the voltage in accordance with the rated voltage
marked on the nameplate?
Is the electrical wiring and piping connection installed
correctly and securely?
Has the unit been connected to a secure earth
connection?
Is the power cord specified?
Has the inlet and outlet been covered?
Has the length of connection pipes and the refrigerant
charge been record?
Possible malfunction
The unit may drop,shake or emit noise.
It may cause insufficient refrigerating capacity.
It may cause condensation and dripping.
It may cause condensation and dripping.
It may cause electric malfunction or damage the part.
It may cause electric malfunction or damage the part.
It may cause electrical leakage.
It may cause electric malfunction or damage the part.
It may cause insufficient refrigerating capacity.
The refrigerating capacity is not accurate