Scanning Information - Viessmann Vitodens 200-W Installation Instructions Manual

4.8 to 35.0 kw wall mounted gas fired condensing boiler natural gas and lpg version
Table of Contents

Advertisement

Scanning information

Subject to connected components, you can scan current temperatures and operating
conditions.
Press the following keys:
i
1.
For boiler water temperature
3
Display indication
1
20ºC
3
65ºC
5
50ºC
5
45ºC
6
70ºC
003572 h
030417
030417
000850 h
°C -
65
Explanation
Outside temperature
Boiler water
temperature
DHW temperature
DHW temperature
for solar operation
Collector temperature
Burner hours run
Burner starts
Fuel consumption
Hours run - solar
circuit pump
_
+
2.
for additional scans
3.
to end scanning
OK
Notes
Display only if an outside
temperature sensor is connected
-
Display only if a DHW cylinder
is installed.
Display only if a solar heating
system is connected.
Display only if a solar heating
system is connected.
The hours run can be reset to 0
by pressing
displayed are only approximate
values.
The number of burner starts can
be reset to 0 by pressing
The fuel consumption can be
reset to 0 by pressing
The hours run can to reset to 0
on the Vitosolic solar control unit.
The hours run displayed are only
approximate values.
. The hours run
67