Friedrich Breeze BRO412W1A Installation Instructions Manual

Friedrich Breeze BRO412W1A Installation Instructions Manual

Advertisement

Breeze
A revolution in room cooling

Installation Instructions

for BRO412W1A
4000 - 12000 Btu
Friedrich Part No. 96091000

Advertisement

Table of Contents
loading

Summary of Contents for Friedrich Breeze BRO412W1A

  • Page 1: Installation Instructions

    Breeze ™ A revolution in room cooling Installation Instructions for BRO412W1A 4000 - 12000 Btu Friedrich Part No. 96091000...
  • Page 2: What's In The Carton

    What’s in the carton? ITEM PART NUMBER DESCRIPTION REVISION NUMBER 68800065 CONDENSER PAD INSTALLATION SCREW 68800066 SCREW #8 X 5/8” TRUSS HEAD 1. Breeze indoor module with 25 ft. connecting 68800085 SCREW #8 X 1 1/2” PHILLIPS PAN HEAD line attached 68800086 WALL ANCHOR FOR #8 SCREW 2.
  • Page 3 Next, determine how you will connect the indoor and outdoor modules. There are two options available: OPTION 1 is to drill a 3” hole through the wall to pass OPTION 2 is to use the Friedrich SimpleSill™ kit to pass the connecting line through. the connecting pipe through the window. The Simple- Sill™...
  • Page 4 Now that you have determined where the modules will be placed it is time to install the Breeze air conditioning system. STEP 2 – Hang wall mount bracket Using the paper template as a guide locate two studs behind screw hole locations in the template. It is preferrable to mount the hangaing plate on studs.
  • Page 5: Step 4 Line Set Installation

    Option 2: Window Installation Using Friedrich SimpleSill™ A. With the window raised, place one end of the SimpleSill™ into the window opening so it is against the corner of the window frame and sill. Raise the other side of the SimpleSill™ 4” above the window sill. Expand the SimpleSill™ the width of the window and install the securing pin as shown.
  • Page 6 STEP 7 – Connect the quick connector from the indoor line set to the outdoor module. 1. Open lock handle on line-set connec- connector on outdoor unit half way and 5. Grasp lock handle and rotate to its tor by pulling back and rotating toward release outer lock collar.
  • Page 7: Step 10 - Final Preparation

    The outer cover of the Breeze indoor module can be cleaned with a damp cloth. Cleaning the outdoor module can be done by rinsing the module with low pressure water. Refer to friedrich.com for approved coil cleaning agents. Cleaning the filter: The indoor module of the Breeze system has a washable filter that should be inspected and cleaned periodically.
  • Page 8: Remote Control Operation

    Remote Control Operation START / STOP Turns the Breeze unit on or off. DN/UP Arrow Press to raise or lower the temperature setting. Temperature setting range is between 61�F – 86�F. FAN/AUTO Adjusts the fan speed or sets fan to ‘AUTO’ operation. Selectable speeds are LOW, MEDIUM, HIGH or AUTO.

Table of Contents