GAS COOKTOP INSTALLATION INSTRUCTIONS
16

Blower electrical connection

Connect the 5-pin plug on the blower assembly
to the matching 5-pin receptacle on the bottom of
the cooktop.
Fold all wires into the wire box on the end of
the blower conduit. Fasten the wire box to the
cooktop with two #8 x 3/8" making sure that no
wires are trapped.
Figure 23 – CONNECT BLOWER TO COOKTOP
17

Connecting the Ductwork

Connect the ductwork prepared in Steps 8, 9 and
10 to the blower transition duct.
18

Install Pressure Regulator

Install the pressure regulator with the arrow on the
regulator pointing up toward the unit in a position
where you can reach the access cap.
WARNING
DO NOT make the connection too
tight. The regulator is die cast. Overtightening
may crack the regulator resulting in a gas leak
and possible fi re or explosion.
Manual
Flare
Shutoff
Union
Valve
On
Nipple
Off
All connections must be wrench-tightened
Figure 22 – GAS SUPPLY LINE
Figure 24 – GAS SUPPLY LINE
Assemble the fl exible connector from the gas
supply pipe to the pressure regulator in the
following order:
1. manual shutoff valve
2. 1/2" (1.3 cm) nipple
3. 1/2" (1.3 cm) fl are union adapter
4. fl exible connector
5. 1/2" (1.3 cm) fl are union adapter
6. 1/2" (1.3 cm) nipple
7. pressure regulator
Use pipe-joint compound made for use with
Natural and LP/Propane gas to seal all gas
connections. If fl exible connectors are used, be
certain connectors are not kinked.
Figure 25 – PHYSICAL ATTACHMENT OF THE
GAS LINE TO THE COOKTOP
11
GAS FLOW
Pressure
Flare
Regulator
Union
Nipple
Flexible
Access
Connector
Cap