2030-0044
Section
4: lnstallation
2000sri
Equipped
with
4
prong
220
Volt
Plug
Lre21
Before connecting machine, check
and
veriff
incoming power
supply.
The
following
chart displays the required voltages.
Receptacle
Voltages
Connections
Voltaqe
L1
to Ground
11OVac
-120Yac
L2
to Ground
1
1OVac
-
120Vac
L1
to Neutral
1
10Vac
-
120Yac
L2
to Neutral
11OVac
-
120Vac
L1
to
L2
200Vac
-240Yac
Ground
to Neutral
OVac.
Install And Set Jumper Plug
Two adjusfnents
are
required
prior to
connection
to power
source.
The Jumper
Plug
and
Step
Down Transformer must
be
properly connected.
Failure to properly set Jumper Plug and Transformer Connector could result in
MACHINE MALFUNCTION, SHORT
CIRCUIT, BLOWN FUSES, OVERHEATING
OR
DAMAGE TO CIRCUIT BOARDS.
Setting Jumper Plug
1.
Measure Source
Voltage
at
the
wall outlet.
Record
in the comments section
of
the
Installation Checklist.
2.
Remove
electrical enclosure cover to
access
DC
Power
Supply Board.
3.
CAUTION: ESD protection required
4.
Remove the
DC Power Supply Board using the white ejector lever.
5.
Insert Jumper
Plug into Jumper Connection located
on
DC Power
Supply Board.
Acorto
2000sii Technical Support
4-7

Hide quick links: