Installing the SN 5428-2 Chassis

Caution

Installing the SN 5428-2 Chassis

Installing on a Table or a Shelf

Step 1
Step 2
Step 3
Cisco SN 5428-2 Storage Router Hardware Installation Guide
2-6
Verify the site power for the type of device you are installing. Power requirements
are useful for planning the power distribution system needed to support the
storage router. Heat dissipation is an important consideration for sizing the
air-conditioning requirements for an installation. See
power and heat ratings for the storage router.
To prevent a loss of input power, verify that the total maximum load on the circuit
supplying power to the power supply is within the current ratings of the wiring
and breakers.
You can install the SN 5428-2 chassis on a table or a shelf, or in an equipment
rack. The following sections describe the steps required to install the SN 5428-2
chassis:
Installing on a Table or a Shelf, page 2-6
Rack-Mounting the SN 5428-2 Storage Router, page 2-7
Attaching the Optional Cable Guide, page 2-14
Before installing the storage router, read the Site Preparation and Safety Guide to
familiarize yourself with proper site and environmental conditions.
To install the chassis on a table or a shelf, follow these steps:
Locate the four adhesive-backed rubber feet. They are in the accessory kit that is
shipped with the storage router.
Peel the rubber feet from their backing and place the feet, adhesive-side down,
onto the four round recessed areas on the bottom of the chassis.
Place the storage router on a table or a shelf near an AC power source.
Chapter 2
Installing the SN 5428-2 Storage Router
Table A-1 on page A-1
for
OL-4797-01