Kramer VS-88HDCPxl User Manual

8x8 dvi matrix switcher
Hide thumbs Also See for VS-88HDCPxl:

Advertisement

Quick Links

K R A ME R E LE CT R O N IC S L TD .
USER MANUAL
MODEL:
VS-88HDCPxl
8x8 DVI Matrix Switcher
P/N: 2900-300016 Rev 7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VS-88HDCPxl and is the answer not in the manual?

Questions and answers

Summary of Contents for Kramer VS-88HDCPxl

  • Page 1 K R A ME R E LE CT R O N IC S L TD . USER MANUAL MODEL: VS-88HDCPxl 8x8 DVI Matrix Switcher P/N: 2900-300016 Rev 7...
  • Page 3: Table Of Contents

    Technical Specifications Default Communication Parameters Protocol 2000 Figures Figure 1: VS-88HDCPxl 8x8 DVI Matrix Switcher Front Panel Figure 2: VS-88HDCPxl 8x8 DVI Matrix Switcher Rear Panel Figure 3: Connecting to the VS-88HDCPxl Rear Panel Figure 4: SELECTOR Buttons VS-88HDCPxl – Contents...
  • Page 4: Introduction

    1 Introduction Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and affordable solutions to the vast range of problems that confront the video, audio, presentation, and broadcasting professional on a daily basis. In recent years, we have redesigned and upgraded...
  • Page 5: Getting Started

    Achieving the Best Performance To achieve the best performance:  Use only good quality connection cables (we recommend Kramer high- performance, high-resolution cables) to avoid interference, deterioration in signal quality due to poor matching, and elevated noise levels (often associated with low quality cables) ...
  • Page 6: Safety Instructions

    Kramer Electronics has made arrangements with the European Advanced Recycling Network (EARN) and will cover any costs of treatment, recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN facility. For details of Kramer’s recycling arrangements in your particular country go to our recycling pages at http://www.kramerelectronics.com/support/recycling/.
  • Page 7: Overview

    3 Overview The high-quality Kramer VS-88HDCPxl is an HDCP compatible 8 x 8 DVI Matrix Switcher that accepts up to eight DVI inputs and routes the selected DVI input signal to any or all of eight DVI outputs. Note that only the digital signal (DVI-D) is available on the DVI connector.
  • Page 8: About Fast Switching

    You can control the VS-88HDCPxl using the front panel buttons or remotely via:  RS-232 serial commands transmitted by a touch screen system, PC or other serial controller  The Kramer infrared remote control transmitter  The Ethernet port ...
  • Page 9: Figure 1: Vs-88Hdcpxl 8X8 Dvi Matrix Switcher Front Panel

    Figure 1: VS-88HDCPxl 8x8 DVI Matrix Switcher Front Panel Feature Function IR Receiver and LED IR remote control sensor. LED lights yellow when receiving an IR signal POWER LED Lights green when the unit is turned on ALL Button Press to select all inputs or all outputs (see Section 6.1)
  • Page 10: Figure 2: Vs-88Hdcpxl 8X8 Dvi Matrix Switcher Rear Panel

    Figure 2: VS-88HDCPxl 8x8 DVI Matrix Switcher Rear Panel Feature Function INPUT DVI Connectors Connect to the DVI sources (from 1 to 8) RS-232 9-pin D-sub (F) Connector Connect to a PC or the serial remote controller (see Section ETHERNET RJ-45 Connector...
  • Page 11: Using The Ir Transmitter

    This distance can be extended to up to 60 meters when used with three extension cables (Model: C-A35M/A35F-50). Before using the external IR receiver, be sure to arrange for your Kramer dealer to insert the internal IR connection cable (P/N: 505-70434010-S) with the 3.5mm connector that fits into the REMOTE IR opening on the rear panel.
  • Page 12: Installing In A Rack

    4 Installing in a Rack VS-88HDCPxl - Installing in a Rack...
  • Page 13: Connecting The Vs-88Hdcpxl

    VS-88HDCPxl. After connecting your VS-88HDCPxl, connect its power and then switch on the power to each device. To connect the VS-88HDCPxl as illustrated in the example in Figure 1. Connect up to eight DVI sources (for example, DVD players) to the IN DVI connectors.
  • Page 14: Connecting To The Vs-88Hdcpxl Via Rs-232

    Figure 3: Connecting to the VS-88HDCPxl Rear Panel Connecting to the VS-88HDCPxl via RS-232 You can connect to the VS-88HDCPxl via an RS-232 connection using, for example, a PC. Note that a null-modem adapter/connection is not required. To connect to the VS-88HDCPxl via RS-232: ...
  • Page 15: Connecting Via Ethernet

    5.2.2 Connecting the Ethernet Port via a Network Hub or Switch You can connect the Ethernet port of the VS-88HDCPxl to the Ethernet port on a network hub or using a straight-through cable with RJ-45 connectors. VS-88HDCPxl - Connecting the VS-88HDCPxl...
  • Page 16: Operating The Vs-88Hdcpxl 8X8 Dvi Matrix Switcher

    Press the OUT button of the output to disconnect and press OFF To disconnect all outputs at once:  Press the ALL button and then press OFF. This disconnects all the outputs VS-88HDCPxl - Operating the VS-88HDCPxl 8x8 DVI Matrix Switcher...
  • Page 17: Storing And Recalling A Setup

    2. Press the relevant OUT or IN button that stored the setup. In this example, press OUT 2 for preset 10. 3. Press the RCL button to recall the stored setup. VS-88HDCPxl - Operating the VS-88HDCPxl 8x8 DVI Matrix Switcher...
  • Page 18: Changing The Port Switching Speed

    Note: If the LOCK button is not pressed within about 12 seconds, the device exits the port speed switching mode automatically and all changes are lost. VS-88HDCPxl - Operating the VS-88HDCPxl 8x8 DVI Matrix Switcher...
  • Page 19: Setting Hdcp To On/Off

    One output set to one or more of the four inputs (see Section 6.6.1)  Different outputs set to different inputs (see Section 6.6.2)  The default EDID (see Section 6.6.3) VS-88HDCPxl - Operating the VS-88HDCPxl 8x8 DVI Matrix Switcher...
  • Page 20 4. Press the SELECT OUT button from which the first EDID is to be acquired (for example, OUT 1). 5. Press the SELECT IN 1 button again. The IN 1 button stops flashing. VS-88HDCPxl - Operating the VS-88HDCPxl 8x8 DVI Matrix Switcher...
  • Page 21: Locking And Unlocking The Front Panel

    Locking and Unlocking the Front Panel To prevent unintended tampering with the unit via the front panel buttons, lock your VS-88HDCPxl. To lock the VS-88HDCPxl:  Press the PANEL LOCK button on the front VS-88HDCPxl - Operating the VS-88HDCPxl 8x8 DVI Matrix Switcher...
  • Page 22: Resetting The Ethernet Configuration To Default Values

    Ethernet port on your PC. Use your PC to configure the initial settings (see Section 5.1). 6.10 Firmware Upgrade Instructions for upgrading the firmware can be found in the STC Firmware Upgrade document. VS-88HDCPxl - Operating the VS-88HDCPxl 8x8 DVI Matrix Switcher...
  • Page 23: Technical Specifications

    DIMENSIONS: 19" x 7" x 2U W, D, H WEIGHT: 2.5kg (5.5lbs) approx. Power cord, IR transmitter, rack “ears” INCLUDED ACCESSORIES: OPTIONS: External remote IR receiver cable Specifications are subject to change without notice at http://www.kramerelectronics.com VS-88HDCPxl - Technical Specifications...
  • Page 24: Default Communication Parameters

    Protocol 2000 Baud Rate: 9600 Data Bits: Stop Bits: Parity: None Command Format: Example (Output 1 to Input 1): 0x01, 0x81, 0x81, 0x81 Ethernet IP Address: 192.168.1.39 TCP Port: 5000 UDP Port 50000 Subnet Mask: 255.255.255.0 VS-88HDCPxl - Default Communication Parameters...
  • Page 25: Protocol 2000

    9 Protocol 2000 The Kramer Protocol 2000 RS-232/RS-485 communication uses four bytes of information as defined below. DESTINATION INSTRUCTION 1st Byte INPUT 2nd Byte 3rd Byte OUTPUT 4th Byte MACHINE NUMBER Bit 7 – Defined as 0. 1st BYTE: D – “DESTINATION”: 0 - for sending information to the switchers (from the PC);...
  • Page 26 PC the same four bytes that it was sent (except for the first byte, where the DESTINATION bit is set high). NOTE 3 - SETUP # 0 is the present setting. SETUP # 1 and higher are the settings saved in the switcher's memory, (i.e. those used for Store and Recall). VS-88HDCPxl - Protocol 2000...
  • Page 27 NOTE 16 - The reply to the “REQUEST WHETHER PANEL IS LOCKED” is as in NOTE 4 above, except that here the OUTPUT is assigned with the value 0 if the panel is unlocked, or 1 if it is locked. VS-88HDCPxl - Protocol 2000...
  • Page 29 For the latest information on our products and a list of Kramer distributors, visit our Web site where updates to this user manual may be found. We welcome your questions, comments, and feedback. Web site: www.kramerelectronics.com E-mail: info@kramerel.com SAFETY WARNING...

Table of Contents