GROUP 6: Accessories and Rack Adapters; GROUP 7: Scan Converters and Scalers; and GROUP 8: Cables and Connectors 2 Download up-to-date Kramer user manuals from the Internet at this URL: http://www.kramerelectronics.com 3 The complete list of Kramer cables is on our Web site at http://www.kramerelectronics.com...
Page 4
Getting Started KRAMER: SIMPLE CREATIVE TECHNOLOGY...
A Take button for the execution of multiple switches all at once A 7-segment display The VS-88HD, which is housed in a 19" 1U rack mountable enclosure, and is fed from a 90-240 VAC universal switching power supply, can be controlled...
Your VS-88HD 8x8 SD/HD-SDI Matrix Switcher Table 1: Front Panel VS-88HD 8x8 SD/HD-SDI Matrix Switcher Feature Function POWER Switch Illuminated switch for turning the unit ON or OFF OFF Button An OFF-OUT combination disconnects that output from the inputs; an...
Installing on a Rack Installing on a Rack This section describes what to do before installing on a rack and how to rack mount. KRAMER: SIMPLE CREATIVE TECHNOLOGY...
RS-485 port (see section 6.3), and/or Connect the power cord 1 Switch OFF the power on each device before connecting it to your VS-88HD. After connecting your VS-88HD, switch on its power and then switch on the power on each device...
Connecting Your VS-88HD 8x8 SD/HD-SDI Matrix Switcher Figure 2: Connecting the VS-88HD 8x8 SD/HD-SDI Matrix Switcher 6.1 Dipswitch Settings By default, all dipswitches are set to OFF. Figure 3 illustrates the VS-88HD dipswitches: Figure 3: Dipswitches KRAMER: SIMPLE CREATIVE TECHNOLOGY...
The Machine # determines the position of a VS-88HD unit, specifying which VS-88HD unit is being controlled when several VS-88HD units connect to a PC or serial controller. Set the Machine # on a VS-88HD unit via SETUP DIPS 1, 2, 3 and 4, according to Table 3.
“G” (Ground) PIN of the first unit). Set the first VS-88HD unit as MACHINE # 1 and the following seven VS-88HD units as MACHINE # 2 to MACHINE # 8, according to Table 3. Figure 5: Controlling via RS-485 (for example, using an RC-3000)
7.2 Confirming Settings Choose to work in the AT ONCE or the CONFIRM mode (see section 0). When the VS-88HD operates in the AT ONCE mode, pressing an OUT-IN combination implements the switch immediately. In the CONFIRM mode, the TAKE button must be pressed to authorize the switch.
Operating the VS-88HD 7.2.1 Toggling between the AT ONCE and CONFIRM Modes To toggle between the AT ONCE and CONFIRM modes, do the following: Press the dim TAKE button to toggle from the AT ONCE mode (in which the TAKE button is dim) to the CONFIRM mode (in which the TAKE button illuminates).
Table of Hex Codes for Serial Communication Table of Hex Codes for Serial Communication Table 5 lists the Hex values for a single machine (MACHINE # 1): Table 5: VS-88HD Hex Codes for Switching via RS-232/RS-485 OUT 1 OUT 2...
Kramer Protocol 2000 10 Kramer Protocol 2000 The VS-88HD is compatible with Kramer’s Protocol 2000 (version 0.48) (below). This RS-232/RS-485 communication protocol uses four bytes of information as defined below. For RS-232, a null-modem connection between the machine and controller is used. The default data rate is 9600 baud, with no parity, 8 data bits and 1 stop bit.
MACHINE ADDRESS 1 - for audio REQUEST WHETHER SETUP # 0 - for checking if setup is defined SETUP IS DEFINED / 1 - for checking if input is valid VALID INPUT IS Input # DETECTED KRAMER: SIMPLE CREATIVE TECHNOLOGY...
Page 19
Kramer Protocol 2000 INSTRUCTION DEFINITION FOR SPECIFIC INSTRUCTION NOTE DESCRIPTION INPUT OUTPUT ERROR / BUSY For invalid / valid input (i.e. OUTPUT 0 - error 9, 25 byte = 4 or OUTPUT byte = 5), 1 - invalid instruction this byte is set as the input #...
Page 20
OUTPUT byte set as 7, the VIS source is the output selected using the OUTPUT byte. Note also, that on some machines the sync source is not software selectable, but is selected using switches, jumpers, etc! KRAMER: SIMPLE CREATIVE TECHNOLOGY...
Page 21
Kramer Protocol 2000 NOTE 6 – If INPUT is set to 127 for these instructions, then, if the function is defined on this machine, it replies with OUTPUT=1. If the function is not defined, then the machine replies with OUTPUT=0, or with an error (invalid instruction code).
Page 22
(in real-time). For example, if input 3 is detected as invalid, the unit will send the HEX codes If input 7 is detected as valid, then the unit will send HEX codes KRAMER: SIMPLE CREATIVE TECHNOLOGY...
Page 24
For the latest information on our products and a list of Kramer distributors, visit our Web site: www.kramerelectronics.com, where updates to this user manual may be found. We welcome your questions, comments and feedback. Safety Warning: Disconnect the unit from the power supply before opening/servicing.