Your VS-88HDxl 8x8 3G SD/HD-SDI Matrix Switcher Using the IR Transmitter Installing the VS-88HDxl in a Rack Connecting the VS-88HDxl Connecting the VS-88HDxl in the Single Link Mode Connecting the VS-88HDxl in the Dual Link Mode Setting the Working Mode Connecting the RS-232 Port 6.4.1...
2 We recommend that you use only the power cord supplied with this device 3 Download up-to-date Kramer user manuals from our Web site at http://www.kramerelectronics.com 4 The complete list of Kramer cables is on our Web site at http://www.kramerelectronics.com...
SMPTE RP-168 The VS-88HDxl is housed in a 19" 1U rack-mountable enclosure, and is fed from a 100-240 VAC universal switching power supply. The unit can be controlled via the front panel buttons or via: •...
VS-88HDxl away from moisture, excessive sunlight and dust Your VS-88HDxl 8x8 3G SD/HD-SDI Matrix Switcher Figure Table 1, and Table 2 define the VS-88HDxl 8x8 3G SD/HD-SDI Matrix Switcher. 1 Available from Kramer Electronics on our Web site at http://www.kramerelectronics.com KRAMER: SIMPLE CREATIVE TECHNOLOGY...
2 Optional. Can be used instead of the front panel (built-in) IR receiver to remotely control the VS-88HDxl (only if the internal IR connection cable has been installed) (See section 4.1)
This distance can be extended to up to 60 meters when used with three extension cables Before using the external IR receiver, be sure to arrange for your Kramer dealer to insert the internal IR connection cable with the 3.5mm connector 1 2 F that fits into the REMOTE IR opening on the rear panel.
Installing the VS-88HDxl in a Rack Installing the VS-88HDxl in a Rack This section provides instructions for rack mounting the 1U unit. KRAMER: SIMPLE CREATIVE TECHNOLOGY...
• ETHERNET connector (see section 6.7) 6. Connect the power cord 1 Switch OFF the power on each device before connecting it to your VS-88HDxl. After connecting your VS-88HDxl, switch on its power and then switch on the power on each device...
1 The graphic on the rear panel does not indicate the dual link connections 2 Switch OFF the power on each device before connecting it to your VS-88HDxl. After connecting your VS-88HDxl, switch on its power and then switch on the power on each device...
Connecting the RS-232 Port You can connect to the VS-88HDxl via an RS-232 connection using, for example, a PC. Note that a null-modem adapter/connection is not required. To connect to the VS-88HDxl via RS-232: •...
Connecting the VS-88HDxl Table 3: Machine # DIP-Switch Settings DIP-SWITCH Machine # 1 (Single or master unit Note: After changing the address, the device must be reset by turning OFF and ON. 6.4.2 Setting the DIP-Switches When controlling a unit via the RS-232 or RS-485 ports set the DIP-switches on the rear of the unit.
OFF. Connecting a PC or Controller to the RS-485 Port You can operate the VS-88HDxl via the RS-485 port from a distance of up to 1200 meters (3900ft) using any device equipped with an RS-485 port (for example, a PC).
6.7.1 Connecting the ETHERNET Port Directly to a PC (Crossover Cable) You can connect the Ethernet port of the VS-88HDxl to the Ethernet port on your PC, via a crossover cable with RJ-45 connectors. This type of connection is recommended for identification of the factory default...
Connecting the VS-88HDxl 1. Right-click the My Network Places icon on your desktop. 2. Select Properties. 3. Right-click Local Area Connection Properties. 4. Select Properties. The Local Area Connection Properties window appears. 5. Select the Internet Protocol (TCP/IP) and click the Properties Button (see...
Connecting the VS-88HDxl 6.7.2 Connecting the ETHERNET Port via a Network Hub (Straight- Through Cable) You can connect the Ethernet port of the VS-88HDxl to the Ethernet port on a network hub or network router, via a straight-through cable with RJ-45 connectors.
4. If required, make changes and press Set. If not, click Close. Controlling via the Ethernet Port You can control the VS-88HDxl via RS-232/RS-485 or the Ethernet using the Kramer K-Router application. If you are controlling a standalone unit via RS-232 or the Ethernet, configure the unit as master (Mach No.
The following operations are performed by using the front panel buttons. 7.1.1 Power On Display When the VS-88HDxl is powered on, the display briefly shows the 4-digit firmware version number, the genlock timing setting, and then the display changes to its normal operating display.
Operating the VS-88HDxl 2. Press an IN SELECT button or the OFF button The selected input switches to the selected output. The digits displayed in the 7-segment display change as appropriate. 7.1.4 Toggling Between Modes To toggle between the AT ONCE and CONFIRM modes, do the following: 1.
Note: Recalling an invalid setup gives an error indication (see section 7.1.10). If you cannot remember which of the eight input/output configurations is the one that you want, set the VS-88HDxl to the CONFIRM mode and manually scan all the input/output configurations until you locate it.
Using Serial Commands To operate the VS-88HDxl using serial commands, Kramer offers control software that can do this. You can download free software from the Kramer Electronics Web site. • For an explanation of all KRAMER 3000 commands, see section •...
Kramer Web site at www.kramerelectronics.com. Changing the Device Parameters To change the device parameters do the following: 1. Connect a PC to the VS-88HDxl using any one of the following connections: • Connect a serial cable from an RS-232 9-pin D-sub rear panel port on the PC to the VS-88HDxl as explained in section 6.4.
Using the P3K Wizard Figure 11: Connect Window 4. Choose the appropriate type of connection: Ethernet BY IP, BY NAME, or SERIAL/USB, and click OK. The Connect window disappears and the Device Properties window appears.
Figure 12: Device Properties Window 5. Change the parameters in the white fields as required and click SET. Updating the VS-88HDxl Firmware The VS-88HDxl uses a microcontroller that runs firmware located in FLASH memory. The latest version of firmware and installation instructions can be downloaded from the Kramer Web site at www.kramerelectronics.com.
0x38, 0x80, 0x83, 0x81 Note: If you are using Kramer’s Windows®-based control software operates only with Protocol 2000. If the VS-88HDxl is set to Protocol 3000, it automatically switches to Protocol 2000. 1 Download the latest software from our Web site at...
Kramer Protocol 3000 10.2 Kramer Protocol 3000 Syntax Protocol 3000 communicates at a data rate of 115200 baud, no parity, 8 data bits and 1 stop bit. 10.2.1 Host Message Format Start Address (optional) Body Delimiter Destination_id@ Message 10.2.1.1 Simple Command...
You can directly enter all commands using a terminal with ASCII communications software, such as HyperTerminal, Hercules, etc. Connect the terminal to the serial or Ethernet port on the Kramer device. To enter press the Enter key. is also sent but is ignored by command parser).
A separate response is sent for every command in the chain. 10.2.7 Maximum String Length 64 characters 10.2.8 Backward Support Protocol 2000 is transparently supported by Protocol 3000. You can switch between protocols using a switch protocol command from either platform. KRAMER: SIMPLE CREATIVE TECHNOLOGY...
Kramer Protocol 3000 10.3 Kramer Protocol 3000 Commands 10.3.1 Device Initiated Messages Command Syntax Switcher actions: Video channel has switched (breakaway mode) VID IN>OUT 10.3.2 Result and Error Codes Syntax Command ran successfully, no error. COMMAND PARAMETERS OK Protocol Errors:...
* Protocol 2000 has a command to switch back to ASCII protocol (like Protocol 3000) 10.3.6 Machine Information Commands Command Syntax Response Read in/out count INFO-IO? INFO-IO: IN INPUTS_COUNT, OUT OUTPUTS_COUNT Read max preset count INFO-PRST? INFO-PRST: VID PRESET_VIDEO_COUNT Reset to factory default FACTORY FACTORY RESULT configuration KRAMER: SIMPLE CREATIVE TECHNOLOGY...
Kramer Protocol 3000 10.3.7 Identification Commands Command Syntax Response Protocol handshaking ~OK CRLF Read device model MODEL? MODEL MACHINE_MODEL Read device serial number SN SERIAL_NUMBER Read device firmware version VERSION? VERSION MAJOR .MINOR .BUILD .REVISION Set machine name NAME NAME MACHINE_NAME RESULT...
Hex Table (Protocol 2000) Hex Table (Protocol 2000) Table 7 lists the Hex values for a single machine (MACHINE # 1): Table 7: VS-88HDxl Hex Codes for Switching via RS-232/RS-485 OUT 1 OUT 2 OUT 3 OUT 4 OUT 5...
Kramer Protocol 2000 Kramer Protocol 2000 The VS-88HDxl is compatible with Kramer’s Protocol 2000 , version 0.50. This RS-232/RS-485 communication protocol uses four bytes of information as defined below. The default data rate is 9600 baud, with no parity, 8 data bits, and 1 stop bit.
OUTPUT is assigned the value of the requested parameter. The replies to instructions 10 and 11 are as per the definitions in instructions 7 and 8 respectively. For example, if the present status of machine number 5 is breakaway setting, then the reply to the HEX code would be HEX codes KRAMER: SIMPLE CREATIVE TECHNOLOGY...
Page 41
Kramer Protocol 2000 NOTE 8 - The reply is as in TYPE 3 above, except that here the OUTPUT is assigned with the value 0 if the setup is not defined / no valid input is detected; or 1 if it is defined / valid input is detected.
Page 42
EXCLUSION OF DAMAGES The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option. Kramer shall not be liable for: 1. Damage to other property caused by defects in this product, damages based upon inconvenience, loss of use of the product, loss of time, commercial loss;...
Page 43
For the latest information on our products and a list of Kramer distributors, visit our Web site: www.kramerelectronics.com where updates to this user manual may be found. We welcome your questions, comments and feedback. Safety Warning: Disconnect the unit from the power supply before opening/servicing.