Built to Perform
Outdoor Concepts Incorporated, 15080 Goldenwest Circle, Westminster, California 92683 (714) 903-1885
www.ociproducts.com

Advertisement

Table of Contents
loading

Summary of Contents for OCI OCIE48EH

  • Page 1 *Because of continuing product improve- ment the specifications in this manual are subject to change without notice. P/N 110254 rev.4 10/2011 ® Built to Perform Outdoor Concepts Incorporated, 15080 Goldenwest Circle, Westminster, California 92683 (714) 903-1885 www.ociproducts.com...
  • Page 2 Elegant Living Overhead Heater - Installation & Operation Guide Model# OCIE48EH ® Built to Perform...
  • Page 3 Welcome hank you for selecting the OCI Outdoor Heater. Because of its unique features,we have developed this Installation and Operation Guide. This guide contains valuable information on how to properly install, use, and care for your new Heater for years of safe and enjoyable use.
  • Page 4: Table Of Contents

    Table of Contents SAFETY PRACTICES & PRECAUTIONS UNPACKING THE HEATER/ITEMS INCLUDED INSTALLATION INSTRUCTIONS BRACKET ASSEMBLY MOUNTING TIPS BATTERY INSTALLATION/CONNECT GAS SUPPLY GAS CONNECTION DIAGRAMS LEAK TESTING TURN POWER ON/LIGHTING & OPERATION INSTRUCTIONS TURN POWER OFF/REMOTE SETUP 14-15 AC POWER HOOKUP WIRING DIAGRAM/SCHEMATIC CONVERTING TO LP OR NATURAL GAS 17-18...
  • Page 5: Safety Practices & Precautions

    Safety Practices and Precautions READ AND UNDERSTAND THESE PRECAUTIONS l When properly cared for, your Heater will give safe, reliable service for many years. However, extreme care must be used since the heater produces intense heat and can increase accident potential. l Read this Care and Use Guide carefully and completely before using your heater to reduce the risk of fire, burn hazard or other injury.
  • Page 6: Safety Practices & Precautions

    Safety Practices and Precautions, Features l Children should not be left alone or unattended in an area where the heater is being used. Never allow them to sit, stand or play on or around the heater at any time. When in use, portions of the heater get hot enough to cause severe burns.
  • Page 7: Unpacking The Heater/Items Included

    (1) AC POWER STEPPER CONVERTOR BOX AF-4000 110H/L (4) AA BATTERIES ***If any of these parts are missing call the OCI parts department @ 714-903-1885 before you attempt to mount or use the heater *Because of continuing product improvement these specifications are subject to change without...
  • Page 8: Installation Instructions

    The OCI Heater provides radiant warmth *indoors (commercial applications only) or outdoors with a powerful 34,000 Btu/hr. All units are equipped with spark igni- tion and 100% shutoff valve for safety. OCI Heaters to be installed in Aircraft Hangers must be installed in accordance with American National Standards for Aircraft Hangers, ANSI/NFPA No.
  • Page 9 Installation WARNING: 1. This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. 2. When Mounting Body Assembly, make sure left hand and right-hand Body assembly are level. If not, escaping heat could easily cause damage to the components inside the compartment.
  • Page 10: Bracket Assembly

    Bracket Assembly Desired heating area coverage MOUNTING COLD/ WELL HEIGHT BREEZY MILD PROTECTED 8-9 ft. 6 ft. X 6 ft. 8 ft. X 8 ft. 10 ft. X 10 ft. Mount bracket Assembly, Wall Mounting: Step one: Locate the (2) Heater Arm Mount Brackets and install them on each end of the Heater using the (2) 1/4-20 X 1/2”...
  • Page 11: Bracket Assembly

    Wall Mounting/Bracket Assembly Step Two, Wall Mounting: Mount the assembled mount brackets on the wall or overhead fixture keeping in mind installation specifications and clearances. The hole to hole dimensions from one bracket to the next should be exactly 48” on center. Mount the brackets into a solid material such as wall studs, Eave Joists, concrete block or com- parable.
  • Page 12: Mounting Tips

    MOUNTING TIPS The heater may be mounted at a 0 degree angle or at a maximum of a 30 degree angle in reference to the floor. The heater must always be horizontal to the floor. WARNING: Mounting the heater at greater than a 30 degree angle will cause improper flue exhaust of combustion gases which may result in dam- age to the front grill and will overheat the electronic control.
  • Page 13: Battery Installation/Connect Gas Supply

    Battery Installation/Connect Gas Supply Battery Installation: Remote Control: The Remote control uses one A23 12v battery installed under the cover on the back of the remote. This battery should be installed at the factory. Heater Control: The Heater Control can be powered by either AC power or DC power. If you are using the DC power option you will need to install four AA 1.5v bat- teries before operating heater.
  • Page 14: Gas Connection Diagrams

    Gas Connection Diagrams Recommended Gas hookup:...
  • Page 15: Leak Testing

    Leak Testing IMPORTANT Ventilation: A minimum building ventilation rate of 4 CFM per 1,000 BTU’s of installed heater input must be provided. This rate of ventilation may be obtained through either gravity or mechanical ventilation of the building. In conjunction with building ventila- tion system,adequate fresh air into the building must be provided through fresh air inlets and/or building inlets.
  • Page 16: Turn Power On/Lighting & Operation Instructions

    Turn Power on/Lighting & Operation Instructions Turn Power on: The OCIE48EH Elite Heater normally operates in a state of readiness meaning that the power to the unit is left in the “remote” position but powers down waiting for a command from the remote control. This uses a minimal drain on the batteries or your household power if you have the heater hooked up to AC power.
  • Page 17: Turn Power Off/Remote Setup

    Once off the Heater defaults to the “HI” setting. Programming the Remote Control: The OCIE48EH must be programmed to the Remote control before it will operate. It is possible to program up to three different remote controls to each heater as well as program infinitely many heaters to one remote control for multiple operation at one time.
  • Page 18: Ac Power Hookup

    Remote setup continued/AC hookup (optional) Programming the Remote Control continued: 2. To program multiple remotes to multiple heaters you will need to turn off the power on all but the current heater that you are programming so that the surrounding heaters do not pick up the signal and program themselves.
  • Page 19: Wiring Diagram/Schematic

    Wiring Diagram/Schematics *Because of continuing product improvement these specifications are subject to change without notice.
  • Page 20: Converting To Lp Or Natural Gas

    Converting to LP or Natural Gas Converting to LP or Natural Gas: In order to change your heater to Natural Gas from LP or vice versa you will need to change three parts as well as change the gas setting on the fuel control: 1.
  • Page 21: Converting To Lp Or Natural Gas

    Converting to LP or Natural Gas (cont’d) Step 3: 1.Locate and remove the aluminum cap on the fuel control by unscrew- ing the cap off. Note: the position of the marker on the shaft of the rotary knob. This mark will point to Nat. or Lp that indicates the type of gas the valve is set 2.
  • Page 22: Clearances

    Warning: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operation and maintenance instructions thoroughly before installing or servicing this equipment. Failure to mount according to these dimensions may void your warranty.
  • Page 23: Care & Cleaning, Troubleshooting

    Care & Cleaning, Troubleshooting Care and Cleaning: To keep your OCI Heater functioning well, we recommend the following to be per- formed annually. 1. With an air hose regulated to 30 psig, blow off any dust and dirt that has accumulat- ed around the burner and inside the control compartment of the heater.
  • Page 24: Heater Servicing

    Symptom: Pilot burner stays on after heater is turned off. 1. Defective gas valve. Contact OCI to replace gas valve. Symptom: Heater operates but makes continuous beeps. 1. Module exceeds designed operating temperature. Improper installation such that the combustion gases flow through the front grill instead of out the top of the heater.
  • Page 25: Heater Parts List

    Heater Parts List ITEM DESCRIPTION PART # LEFT PANEL 130053 TOP PANEL 130051 TOP/BOTTOM HEAT LINER 143774 LEFT BURNER BRACKET 130057 WARP BRACKET 130073 BACK PANEL 130056 HIGH OUTPUT IR BURNER 112040 RIGHT BURNER MOUNT 130058 HEAT SHIELD 130055 RIGHT PANEL 130054 BOTTOM PANEL 130052...
  • Page 26: Warranty

    OCI to be defective. Replacement will be F.O.B. OCI and OCI will not be liable for any transportation costs, labor costs, or export duties. This warranty shall not apply, nor can we assume responsibility for damage that might result from failure to follow manufacturers instructions or local codes,where the appliance has been tampered with or altered in any way or which, in our judgement, has been subjected to misuse, negligence, misinstallation or accident.
  • Page 27: How To Obtain Service

    2) Is there a power outage in the area? 3) Have you checked the batteries? 4) Is the gas supply “on”? For your convenience, product service questions can be answered by an OCI Customer Support Specialist by phone:1-714-903-1885. Monday thru Friday, 8:00 am – 4:00 pm PST.