Bryant PREFERRED 226A Series Product Data

Bryant PREFERRED 226A Series Product Data

Preferred series 2-stage heat pump with puron refrigerant 2 to 5 nominal tons
Hide thumbs Also See for PREFERRED 226A Series:

Advertisement

MODEL 226A
PREFERRED™ SERIES 2- -STAGE HEAT PUMP
®
WITH PURON
REFRIGERANT
2 TO 5 NOMINAL TONS
the environmentally sound refrigerant
Bryant's heat pumps with Puronr refrigerant provide a collection
of features unmatched by any other family of equipment. The
226A has been designed utilizing Bryant's Puron refrigerant. The
environmentally sound refrigerant allows consumers to make a
responsible decision in the protection of the earth's ozone layer.
This product has been designed and manufactured to meet Energy
Starr criteria for energy efficiency when matched with appropriate
coil components. Refer to the combination ratings in the Product
Data for system combinations that meet Energy Starr guidelines.
NOTE: Ratings contained in this document are subject to
change at any time.
Always refer to the AHRI directory
(www.ahridirectory.org) for the most up- -to- -date ratings
information.

Product Data

INDUSTRY LEADING
FEATURES / BENEFITS
Energy Efficiency
S 13.7 - - 17.2 SEER/11.2 - - 13.5 EER/8.0 - - 9.5 HSPF
S Microtube Technologyt refrigeration system
S Indoor air quality accessories available
Sound
S Sound level as low as 70 dBA
Comfort
S System supports Thermidistatt or standard 2- -stage thermostat
controls
Reliability
S Puronr refrigerant - - environmentally sound, won't deplete the
ozone layer and low lifetime service cost.
S Front- -seating service valves
S 2- -stage scroll compressor
S Internal pressure relief valve
TM
S Internal thermal overload
S High pressure switch
S Loss of charge switch
S Filter drier
S Balanced refrigeration system for maximum reliability
Durability
DuraGuard Plust protection package:
S Solid, Durable sheet metal construction
S Steel louver coil guard
S Baked- -on, complete outer coverage, powder paint
Applications
S Long- -line - - up to 250 feet (76.2 m) total equivalent length, up
to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft.
(24.38 m) evaporator above condenser (See Longline Guide for
more information.)

Advertisement

Table of Contents
loading

Summary of Contents for Bryant PREFERRED 226A Series

  • Page 1: Product Data

    S Balanced refrigeration system for maximum reliability of features unmatched by any other family of equipment. The Durability 226A has been designed utilizing Bryant’s Puron refrigerant. The environmentally sound refrigerant allows consumers to make a DuraGuard Plust protection package: responsible decision in the protection of the earth’s ozone layer.
  • Page 2: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE Product Tier SEER Major Voltage Variations Cooling Capacity Open Open Open Series Family Series 2=HP 6=16 SEER A=Puron A = Standard 0=Not 0=Not 0=Not A = Original Legacy 208--- 230--- 1 Defined Defined Defined Series Series or 208/230--- 1 the environmentally sound refrigerant Use of the AHRI Certified TM Mark indicates a...
  • Page 3: Physical Data

    PHYSICAL DATA UNIT SIZE SERIES 024--- B 036--- B 048--- B 060--- C Operating Weight lb (kg) 257 (117) 269 (122) 295 (134) 322 (146) Shipping Weight lb (kg) 301 (137) 313 (142) 339 (154) 368 (167) Compressor Type Ultratechr Scroll REFRIGERANT Puronr (R---410A) Control...
  • Page 4: Refrigerant Piping Length Limitations

    REFRIGERANT PIPING LENGTH LIMITATIONS Maximum Line Lengths: The maximum allowable total equivalent length for heat pumps varies depending on the vertical separation. See the tables below for allowable lengths depending on whether the outdoor unit is on the same level, above or below the outdoor unit. Maximum Line Lengths for Heat Pump Applications MAXIMUM ACTUAL LENGTH MAXIMUM EQUIVALENT LENGTH{...
  • Page 5: Accessory Usage Guideline

    Accessory required to meet AHRI rating and system reliability, where indoor not equipped. 4. Outdoor Air Temperature Sensor Required in all heat pump applications designed with Designed for use with Bryant Thermostats listed in this Puron refrigerant. publication. This device enables the thermostat to display the...
  • Page 6: Electrical Data

    ELECTRICAL DATA UNIT FUSE* OPER VOLTS* COMPR WIRE WIRE LENGTH LENGTH SIZE --- * or SIZE{ SIZE{ ft (m)} ft (m)} V/PH VOLTAGE, SERIES 60°C 75°C 60°C 75°C AMPS 024--- B 58.3 12.5 16.2 48 (14.8) 46 (14.1) 036--- B 83.0 18.5 23.7...
  • Page 11 Wall...
  • Page 21: Guide Specifications General

    GUIDE SPECIFICATIONS AIR- -COOLED, SPLIT- -SYSTEM HEAT PUMP 226A GENERAL 2 TO 5 NOMINAL TONS System Description — Condenser fan motors will be totally enclosed, 1- -phase type with class B insulation and permanently lubricated. Outdoor- -mounted, air- -cooled, split- -system heat pump unit suitable for ground or rooftop installation.