York E*BA-F018 THRU 060 Technical Manual page 4

Split-system heat pumps 10 seer 1.5 thru 5 nominal tons, 1 ph/3 thru 7.5 nominal tons, 3 ph

Advertisement

036-21318-002 Rev. A (0106)
Additional R-22 Charge / Orifice Size for Various Matched Systems - 3 Phase
Outdoor Unit
1
Unit Orifice (s)
Factory R-22 Charge, lbs-oz
Indoor Coil
G1NA036S17L
G1NA048S21D
G1NA048S24P
G1UA048S21
G1UA060S24
G1FA048S21
G1FA060S24
G2FD042(S,H)21
G2FD048(S,H)21/24
G2FD060(S,H)24
F3EH090A33
FOOTNOTES:
1. These orifices are packed in the instruction/warranty packet of each outdoor unit.
2. These orifices are factory mounted in the flow control device of each indoor coil.
3. A TXV is factory mounted in the coil or air handler.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaportor and for 15 feet of intercon-
necting line tubing.
2. Verify the orifice size and additional charge required for specific evaportor coil in the system using the above table.
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above.
4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for
evaportor + adder for line set.
5. If the orifice in the evaportor was changed, verify the evaportor nameplate has been marked with the correct orifice size.
4
EABA-(T,W)036S
71, 75
5 - 12
2
Coil Orifice
67
71 + 7
67
71 + 7
78
84
81 + 13
90
84
81 + 13
90
78
81 + 8
84
90
TXV
EBBA-(T,W)048S
EABA-(T,W)060S
81, 84, 87
99
8 - 3
11 - 3
System Orifice = Additional Charge, Oz
81 + 8
81 + 8
84 + 3
84 + 4
99 + 0
84 + 3
84 + 4
99 + 0
87 + 6
84 + 4
99 + 0
EABA-(T,W)090S
16.0
3
TXV
+ 0
Unitary Products Group