Split-system heat pumps 10 seer 1.5 thru 5 nominal tons, 1 ph/3 thru 7.5 nominal tons, 3 ph

Advertisement

TECHNICAL
TECHNICAL
GUIDE
GUIDE
SPLIT-SYSTEM
HEAT PUMPS
10 SEER
MODELS:
E*BA-F018 THRU 060
(1.5 THRU 5 NOMINAL TONS, 1 PH)
E*BA-(T,W)036 THRU 090
(3 THRU 7.5 NOMINAL TONS, 3 PH)
This product was manufactured
Certification applies only
in a plant whose quality system
when the complete
is certified/registered as being
system is listed
in conformity with ISO 9001.
with ARI.
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ariprimenet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
MODELS: 018 - 060 (1 PH)
MODELS: 036-048 (3 PH)
MODELS: 060, 090 (3 PH)
R
P
DESCRIPTION
The 10 SEER Series heat pumps is the outdoor part of a ver-
satile system of heat pumps. It is designed to be custom-
matched with one of UPG's complete line of evaporator sec-
tions, with each serving a specific function. Matching Air Han-
dlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric Heaters
are available, if required. Add-On coils are available for use
with upflow, downflow, or horizontal furnaces and air han-
dlers.
WARRANTY
Single Phase Units:
5-year limited parts warranty.
5-year limited compressor warranty.
Three Phase Units:
1-year limited parts warranty.
5-year limited compressor warranty.
FEATURES
• QUALITY COILS - The coil is constructed of copper tube and
aluminum fins.
• COIL PROTECTION - Coils are protected from damage by a
polymer mesh applied between the coil face, and a PVC
coated steel coil guard.
• PROTECTED COMPRESSOR - The compressor is internally
protected against high pressure and temperature. This is
accomplished by the simultaneous operation of high pressure
relief valve and a temperature sensor which protects the com-
pressor if undesirable operating conditions occur. A liquid line
filter-drier further protects the compressor.
• DURABLE FINISH - Cabinet is made of pre-painted steel.
The pre-treated flat galvanized steel provides a better paint to
steel bond, which resists corrosion and rust creep. Special
primer formulas and matted-textured finish insure less fading
when exposed to sunlight.
• LOWER INSTALLED COST - Installation time and costs are
reduced by easy power and control wiring connections. Dis-
charge line heat exchanger knockouts are provided, if
required. Available in sweat connect models only. The unit
contains enough refrigerant for matching indoor coils and 15
feet of interconnecting piping. The small base dimension
means less space is required on the ground or roof.
• TOP DISCHARGE - The warm air from the top mounted fan is
blown up away from the structure and any landscaping. This
allows compact location on multi-unit applications.
• LOW OPERATING SOUND LEVEL - The upward air flow car-
ries the normal operating noise away from the living area. The
rigid top panel effectively isolates any motor sound. Isolator
mounted compressor and the rippled fins of the condenser
coil muffle the normal fan motor and compressor operating
sounds.
• LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
• EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections, a single panel covering the electrical controls, and
the molex plug in the control box connecting the condenser
fan make for easy servicing of the unit.
• SECURED SERVICE VALVES - Secured re-usable service
valves are provided on both the liquid and vapor sweat con-
nections for ease of evacuating and charging.
• U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment certifi-
cation program, which is based on ARI Standard 210/240.
036-21318-002 Rev. A (0106)

Advertisement

loading

Summary of Contents for York E*BA-F018 THRU 060

  • Page 1 Certified in accordance with the Unitary Small Equipment certifi- cation program, which is based on ARI Standard 210/240. Visit us on the web at www.york.com for the most up-to-date technical information. Additional rating information can be found at www.ariprimenet.org.
  • Page 2: Physical And Electrical Data 1 Phase

    036-21318-002 Rev. A (0106) Physical and Electrical Data - 1 Phase MODEL EBBA-F018S EBBA-F024S EABA-F030S EABA-F036S EABA-F042S EBBA-F048S EABA-F060S Unit Supply Voltage 208/230 – 1 – 60 187 to 252 Normal Voltage Range Minimum Circuit Ampacity 11.8 14.9 19.0 28.5 31.7 40.7 Max.
  • Page 3 036-21318-002 Rev. A (0106) Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase Outdoor Unit EBBA-F018S EBBA-F024S EABA-F030S EABA-F036S EABA-F042S EBBA-F048S EABA-F060S 51,53 59,61 67, 69 67, 69, 71 75,78,81 81,84,87 Unit Orifice (s) Factory R-22 Charge, lbs-oz 4 - 14 5 - 0 4 - 8...
  • Page 4 036-21318-002 Rev. A (0106) Additional R-22 Charge / Orifice Size for Various Matched Systems - 3 Phase Outdoor Unit EABA-(T,W)036S EBBA-(T,W)048S EABA-(T,W)060S EABA-(T,W)090S 71, 75 81, 84, 87 — Unit Orifice (s) Factory R-22 Charge, lbs-oz 5 - 12 8 - 3 11 - 3 16.0 Indoor Coil...
  • Page 5 036-21318-002 Rev. A (0106) COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING COIL UNIT MODEL NET MBH SEER RATED SEER ELECTRIC MODEL MODEL W/O TXV HEAT KW WITH TXV TOTAL SENS. 1 PH 10 SEER HP WITH N-AH / G2FD EBBA-F018S N1AHB0806 2,5,8,10...
  • Page 6 036-21318-002 Rev. A (0106) COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils FURNACE** COOLING COIL UNIT MODEL NET MBH CFM RANGE RATED SEER SEER + TXV MODEL (MIN.-MAX.) W/O TXV TOTAL SENS. + TDR* 14,17 G1FA024S14,17 17.6 12.7 10.00 8.85 G1FA030S14...
  • Page 7 036-21318-002 Rev. A (0106) COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils (Continued) FURNACE** COOLING COIL UNIT MODEL NET MBH CFM RANGE RATED SEER SEER + TXV MODEL (MIN.-MAX.) W/O TXV TOTAL SENS. + TDR* 21,24 G1FA048S21 1600 44.5 33.1 10.00...
  • Page 8 036-21318-002 Rev. A (0106) HEATING PERFORMANCE - With Furnace Coils ARI HEATING OUTDOOR TEMP UNIT COIL MODEL* 47°F 17°F -3°F 7°F 17°F 27°F 37°F 47°F 57°F MODEL MBH COP MBH COP STD MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW G2FD024(S,H)14,17 17.0 3.02 10.6 2.06 1.41...
  • Page 9: Sound Ratings

    036-21318-002 Rev. A (0106) HEATING PERFORMANCE - With Furnace Coils (Continued) ARI HEATING OUTDOOR TEMP UNIT COIL MODEL* 47°F 17°F -3°F 7°F 17°F 27°F 37°F 47°F 57°F MODEL MBH COP MBH COP STD MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW G2FD048(S,H)21,24 47.0 3.02 31.2 2.32 21.0 3.56 26.1 3.75 31.2 3.94 36.3 4.13 40.1 4.32 47.0 4.56 54.1 4.59...
  • Page 10: Typical Installation

    036-21318-002 Rev. A (0106) TYPICAL INSTALLATION MINIMUM 24” SERVICE ACCESS THERMOSTAT TO FURNACE OR CLEARANCE ON ONE SIDE 60” OVERHEAD AIR HANDLER CLEARANCE WEATHERPROOF TERMINAL BLOCK DISCONNECT SWITCH NEC CLASS 1 WIRING NEC CLASS 2 WIRING 10” CLEARANCE TO INDOOR COIL COIL AREA SEAL OPENING(S) WITH NOTE: ALL OUTDOOR WIRING...
  • Page 11: Unitary Products Group

    036-21318-002 Rev. A (0106) TYPICAL FIELD WIRING - 3 PH (036 - 060) ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES THERMOSTAT INDOOR UNIT OUTDOOR UNIT LOW VOLTAGE TERMINAL BLOCK DEFROST IN AIR HANDLER WITH ELECTRIC HEAT CONTROL CONTACTOR B or C...
  • Page 12: Cooling Performance Data

    036-21318-002 Rev. A (0106) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. EBBA-F018S INDOOR COIL MODEL NO. F2RP/F2FP018 ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 20.8 18.3 15.1 22.4 19.4 16.0 23.1 20.0 16.6 S.C. 11.7 11.0 13.8...
  • Page 13 036-21318-002 Rev. A (0106) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. EBBA-F024S INDOOR COIL MODEL NO. F2RP/F2FP030 ID CFM 1050 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 26.6 24.3 22.4 20.0 27.0 24.7 22.7 20.3 27.1 24.8 22.8 20.9...
  • Page 14 036-21318-002 Rev. A (0106) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. EABA-F030S INDOOR COIL MODEL NO. F2RP/F2FP036 ID CFM 1050 1250 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 27.1 27.3 26.5 28.3 28.3 28.6 28.8 29.1 29.7 S.C.
  • Page 15 036-21318-002 Rev. A (0106) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. EABA-F036S, EABA-(T,W)036S) INDOOR COIL MODEL NO. F2RP/F2FP036 ID CFM 1000 1250 1400 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 38.1 35.0 32.5 29.4 38.6 35.5 32.9 29.9 38.8...
  • Page 16 036-21318-002 Rev. A (0106) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. EABA-F042S INDOOR COIL MODEL NO. F2RP/F2FP042 ID CFM 1200 1400 1600 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 44.8 42.1 38.8 45.8 43.0 40.4 46.2 43.5 40.9 S.C.
  • Page 17 036-21318-002 Rev. A (0106) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. EBBA-F048S, EBBA-(T,W)048S INDOOR COIL MODEL NO. F2FP048 ID CFM 1300 1450 1550 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 52.3 48.3 45.0 40.6 53.0 49.0 45.7 41.3 53.4...
  • Page 18 036-21318-002 Rev. A (0106) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. EABA-F060S INDOOR COIL MODEL NO. F2FP060 ID CFM 1550 1750 1950 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 62.6 57.9 53.9 48.8 63.6 58.8 54.9 49.7 64.1 59.4...
  • Page 19 036-21318-002 Rev. A (0106) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. EABA-(T,W)060S) INDOOR COIL MODEL NO. G2FD060(S,H)24 ID CFM 1600 1800 2000 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 63.0 61.1 60.7 62.9 60.9 61.1 62.9 60.6 61.4 S.C.
  • Page 20 036-21318-002 Rev. A (0106) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. EABA-(T,W)090S INDOOR COIL MODEL NO. FCEH090 ID CFM 2400 3000 3600 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 103.9 94.3 88.5 107.3 98.0 92.1 110.6 101.8 95.7 S.C.
  • Page 21: Heating Performance Data

    036-21318-002 Rev. A (0106) HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO. EBBA-F018S EVAPORATOR COIL MODEL NO. F2RP/F2FP018 AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING OUTDOOR INDOOR C.O.P. MBTUH C.O.P. MBTUH C.O.P. MBTUH UNIT COIL 21.1 1.70 3.66 21.8 1.70 3.76 22.0 1.57...
  • Page 22 036-21318-002 Rev. A (0106) HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO. EBBA-F024S EVAPORATOR COIL MODEL NO. F2RP/F2FP030 AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING 1050 OUTDOOR INDOOR MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. UNIT COIL 27.4 2.01 4.00 27.6 1.98 4.09 27.1...
  • Page 23 036-21318-002 Rev. A (0106) HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO EABA-F030S EVAPORATOR COIL MODEL NO F2RP/F2FP036 AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING 1050 1250 OUTDOOR INDOOR MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. UNIT COIL 35.4 2.72 3.82 35.7 2.71 3.87...
  • Page 24 036-21318-002 Rev. A (0106) HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO EABA-F036S, EABA-(T,W)036S EVAPORATOR COIL MODEL NO F2RP/F2FP036 AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING 1000 1250 1400 OUTDOOR INDOOR MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. UNIT COIL 41.6 3.37 3.62 42.0...
  • Page 25 036-21318-002 Rev. A (0106) HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO EABA-F042S EVAPORATOR COIL MODEL NO F2RP/F2FP042 AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING 1200 1400 1600 OUTDOOR INDOOR MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. UNIT COIL 48.5 3.39 4.21 47.4 3.30...
  • Page 26 036-21318-002 Rev. A (0106) HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO EBBA-F048S, EBBA-(T,W)048S EVAPORATOR COIL MODEL NO F2RP/F2FP048 AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING 1250 1400 1550 OUTDOOR INDOOR MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. UNIT COIL 53.4 4.86 3.23 52.9...
  • Page 27 036-21318-002 Rev. A (0106) HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO EABA-F060S EVAPORATOR COIL MODEL NO F2FP060 AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING 1550 1750 1950 OUTDOOR INDOOR MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. UNIT COIL 64.7 5.61 3.38 62.9 5.42...
  • Page 28 036-21318-002 Rev. A (0106) HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO EABA-(T,W)060S EVAPORATOR COIL MODEL NO G2FD060(S,H)24 AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING 1600 1800 2000 OUTDOOR INDOOR MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. UNIT COIL 63.6 5.09 3.67 61.9 4.98...
  • Page 29 036-21318-002 Rev. A (0106) HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO EABA-(T,W)090S EVAPORATOR COIL MODEL NO FCEH090 AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING 1550 1750 1950 OUTDOOR INDOOR MBTUH K.W. C.O.P. MBTUH K.W. C.O.P. MBTUH K.W. C.O.P. UNIT COIL 94.5 8.93...
  • Page 30 036-21318-002 Rev. A (0106) MATCHING INDOOR COMPONENTS ADD-ON COILS - FOR FURNACE APPLICATIONS G1NA G1UA UPFLOW G1HD UPFLOW HORIZONTAL DUCT G2FD* MULTI-POSITION G1FA (UPFLOW, HORIZONTAL FULL CASED AND DOWNFLOW) * Available with factory installed horizontal drain pan. AIR HANDLERS - FOR NON-FURNACE APPLICATIONS N1AH OR N1VS MODULAR BLOWER (UPFLOW, HORIZONTAL...
  • Page 31 036-21318-002 Rev. A (0106) NOTES Unitary Products Group...
  • Page 32 Subject to change without notice. Printed in U.S.A. 036-21318-002 Rev. A (0106) Copyright © by York International Corp. 2006. All rights reserved. Supersedes: 036-21318-001 Rev. C (0403) Unitary 5005 Norman Product York Group Drive 73069...