DLCC SETUP

RESTORE DEFAULT

Whenever necessary, send the following string to DLCC via COM Port to restore its
default values. Otherwise skip to step 2:
1.
Restore DLCC Default
This command does not change the DLCC address nor the destination device
addresses, nor the RF Baud Rate parameters.

SET RADIO ADDRESSES

Follow the procedure below to set the DLCC radio address and prepare it to receive
and transmit data to all devices included in the range from the First to the Last
destination device.
2.
Enter Configuration
3.
Set DLCC Radio Address
xxxx = four digits for the DLCC address (from 0000 to 1999).
This address must be unique.
4.
First Destination Device Address
xxxx = four digits for the Destination Device address (from
0000 to 1999).
5.
Last Destination Device Address
xxxx = four digits for the Destination Device address (from
0000 to 1999).
If transmitting to one Destination device only, this selection
is not required.
6.
Exit and Save Configuration
Step 4 and 5 can be omitted when the card is used only to receive data (Server).
When a range of cable-connected destination devices (i.e. a Stargate™ RS485
network) is defined, DLCC activates roaming towards all these devices.
4
DL CORDLESS CARD™
$+$*CR
$+
RCxxxx
MSxxxx
MTxxxx
$-CR