Control units
(cont.)
Note
For further information, see www.vitocom.info.
Configuration:
Mobile phones via SMS
Standard delivery:
■ Vitocom 100 with integral mobile phone modem.
■ Connecting cable with Rast 5 system connectors for connection to
the control unit KM BUS.
■ Mobile aerial (3.0 m long), magnetic base and adhesive pad.
■ Power cable with plug-in power supply unit (2.0 m long).
On-site requirements:
■ Good reception for GSM communication with the selected mobile
phone operator.
■ Total length of all KM BUS subscriber cables up to 50 m.
Specification
2 6
3 4

Vitocom 200

For part no., see the current pricelist
■ Type LAN2
For remote monitoring, remote control and remote setup of all heat-
ing circuits in a heating system via IP networks (LAN)
As an internet data transfer establishes a permanent connection
("always online"), access to the heating system is particularly fast.
Storage combi boiler for wall mounting.
For system operation with Vitotrol app, Vitodata 100 or
Vitodata 300.
Functions when operating with Vitotrol app:
■ Remote control of up to 3 heating circuits in one heating system.
■ Setting of operating programs, set values and time programs.
■ Calling up of system information.
■ Displaying messages on the Vitotrol app user interface.
The Vitotrol app supports the following end devices:
■ End devices with Apple iOS operating system, versions 5.0 and 6.0.
■ End devices with Google Android operating system, version 4.0 and
higher.
VITODENS
. 5
Power supply via plug-in power sup-
ply unit
Rated current
Power consumption
Safety category
IP rating
Mode of operation
Permissible ambient temperature
– During operation
– During storage and transport
On-site connection
Note
For more information, see www.vitotrol-app.info.
Functions when operating with Vitodata 100:
For all heating circuits in a heating system:
■ Remote monitoring:
– Forwarding messages via email to terminal devices with email cli-
ent function.
– Forwarding messages via SMS to mobile phone/smartphone or
fax (via chargeable internet service Vitodata 100 fault manage-
ment).
– Monitoring additional devices via the inputs and output of the
Vitocom 200.
■ Remote control:
Adjusting operating programs, set values, time programs and heat-
ing curves.
Note
■ Telecommunication costs for data transfer are not included in the
price of the device.
■ For more information, see www.vitodata.info.
230 V~/5 V–
1.6 A
5 W
II
IP 30 to EN 60529, ensure
through design/installation
Type 1B to EN 60730-1
0 to +50 °C
Installation in living spaces or
boiler rooms (standard ambi-
ent conditions)
–20 to +85 °C
Digital input:
Floating contact
VIESMANN