Viessmann VITODENS 300-W Technical Manual page 7

Vitodens series gas condensing boiler
Hide thumbs Also See for VITODENS 300-W:
Table of Contents

Advertisement

Vitodens 200-W
(cont.)
Gas boiler, series B and C,
Category II
2N3P
Type
Rated heating output range (to EN 677)
T
/T
= 50/30 °C
F
R
T
/T
= 80/60 °C
F
R
*2
Flue gas parameters
Flue gas category to G 635/G 636
Temperature (at a return temperature of
30 °C)
– at rated heating output (DHW heating)
– at partial load
Temperature (at a return temperature of
60 °C)
Mass flow rate
Natural gas
– at rated heating output (DHW heating)
– at partial load
LPG
– at rated heating output (DHW heating)
– at partial load
Available draught
Standard seasonal efficiency [to DIN]
at T
/T
= 40/30 °C
F
R
Max. amount of condensate
to DWA-A 251
Internal diameter of the pipe to the safety
valve
Condensate connection (hose nozzle)
Flue gas connection
Ventilation air connection
Gas condensing combi boiler
Gas boiler, series B and C,
Category II
2N3P
Type
Rated heating output range (to EN 677)
T
/T
= 50/30 °C
F
R
T
/T
= 80/60 °C
F
R
Rated heating output range for DHW heating
Rated heat input
Product ID
IP rating
Gas supply pressure
Natural gas
LPG
Max. permissible gas supply pressure
Natural gas
LPG
Power consumption
– In delivered condition
– Max.
Weight
Heat exchanger content
Max. flow rate
(limit for the use of hydraulic separation)
*2
Calculation values for sizing the flue system to EN 13384.
Flue gas temperatures as actual gross values at 20 °C combustion air temperature.
The flue gas temperature at a return temperature of 30 °C is significant for the sizing of the flue system.
The flue gas temperature at a return temperature of 60 °C is used to determine the application range of flue pipes with maximum permissible
operating temperatures.
*3
If the gas supply pressure is higher than the maximum permissible value, install a separate gas pressure governor upstream of the system.
VITODENS
kW
3.2 (4.8) - 13.0
kW
2.9 (4.3) - 11.8
G
/G
52
°C
°C
°C
kg/h
29.7
kg/h
kg/h
28.2
kg/h
Pa
250
mbar
%
l/h
DN
Ø mm
20-24
Ø mm
Ø mm
100
kW
kW
kW
kW
mbar
kPa
mbar
kPa
*3
mbar
kPa
mbar
kPa
W
W
kg
l
l/h
B2HA
Values in ( ) when operating with LPG P
3.2 (4.8) - 19.0
5.2 (8.8) - 26.0
2.9 (4.3) - 17.2
4.7 (8.0) - 23.7
G
/G
51
52
51
45
45
35
35
68
68
31.8
5.5
5.5
30.2
7.6
7.6
250
2.5
2.5
up to 98 (H
) [gross cv] / 109 (H
s
2.3
2.5
15
15
20-24
60
60
100
B2KA
Values in ( ) when operating with LPG P
5.2 (8.8) - 26.0
4.7 (8.0) - 23.7
4.7 (8.0) - 29.3
4.9 (8.3) - 30.5
CE-0085CN0050
IP X4D to EN 60529
20
2
50
5
25.0
2.5
57.5
5.75
68
114
46
2.4
1400
5.2 (8.8) - 35.0
4.7 (8.0) - 31.7
G
/G
G
/G
52
51
52
51
45
45
35
35
70
70
43.9
58.7
8.7
8.7
41.7
55.7
14.0
14.0
250
250
2.5
2.5
) [net cv]
i
3.5
4.6
15
15
20-24
20-24
60
60
100
100
5.2 (8.8) - 35.0
4.7 (8.0) - 31.7
4.7 (8.0) - 33.5
4.9 (8.3) - 34.9
20
2
50
5
25.0
2.5
57.5
5.75
89
126
48
2.8
1600
VIESMANN
7
1