Vitocom 100, Type Lan1; Vitocom 100, Type Gsm2 - Viessmann VITODENS 300-W Technical Manual

Vitodens series gas condensing boiler
Hide thumbs Also See for VITODENS 300-W:
Table of Contents

Advertisement

Control units
(cont.)
Rated current
Power consumption
Rated breaking capacity of the relay
output
Safety category
IP rating

Vitocom 100, type LAN1

Part no. Z011 224
■ With communication module
■ For remote control of a heating system via the internet and IP net-
works (LAN) with DSL router.
■ Compact device for wall mounting.
■ For system operation with the Vitotrol app or Vitodata 100.
Functions when operating with the Vitotrol app:
■ Remote control of up to three heating circuits in one heating system.
■ Setting of operating programs, set values and time programs.
■ Scanning system information
■ Displaying messages on the Vitotrol app user interface
The Vitotrol app supports the following end devices:
■ End devices with Apple iOS operating system, versions 5.0 and 6.0.
■ End devices with Google Android operating system, version 4.0 and
higher.
Note
For more information, see www.vitotrol-app.info.
Functions when operating with Vitodata 100:
For all heating circuits in a heating system:
■ Remote monitoring:
– Forwarding of messages by email to end devices with email client
functionality.
– Forwarding messages via SMS to mobile phone/smartphone or
fax (via chargeable internet service Vitodata 100 fault manage-
ment).
■ Remote control:
Adjusting operating programs, set values, time programs and heat-
ing curves.
Note
For more information, see www.vitodata.info.
Configuration:
Configuration takes place automatically.
When the DHCP service is enabled, no adjustments have to be made
on the DSL router.
Standard delivery:
7
■ Vitocom 100, type LAN1 with LAN socket.
■ LON communication module for installation in the Vitotronic control
unit.
■ Connecting cables for LAN and LON communication module.
■ Power cable with plug-in power supply unit.
■ Vitodata 100 fault management for a duration of 3 years.

Vitocom 100, type GSM2

For part no., see the current pricelist
For remote monitoring and remote control of a heating system via
mobile phone networks.
For the transmission of messages and settings for operating programs
by means of SMS.
Storage combi boiler.
VIESMANN
98
2 A
Permissible ambient temperature
4 W
– During operation
2(1) A 250 V~
I
IP 20 D to EN 60529
– During storage and transport
Ensure through design/instal-
lation
On-site requirements:
■ The LON communication module must be installed in the control unit.
■ Before commissioning, check the system requirements for commu-
■ Internet connection with flat rate data (without time or volume
■ DSL router with dynamic IP addressing (DHCP).
Note
For information on registering and using the Vitotrol app and
Vitodata 100, see www.vitodata.info.
Specification
Power supply via plug-in power sup-
ply unit
Rated current
Power consumption
Safety category
IP rating
Permissible ambient temperature
– During operation
– During storage and transport
Functions:
■ Remote monitoring via SMS to 1 or 2 mobile phones
■ Remote monitoring of additional systems via digital input (floating
■ Remote setup with mobile phone via SMS
■ Operation with mobile phone via SMS
nication via the IP networks (LAN).
restrictions).
3 4
contact)
0 to +40 °C
Installation in living spaces or
boiler rooms
(standard ambient conditions)
–20 to +65 °C
230 V~/5 V–
250 mA
8 W
II
IP 30 to EN 60529, ensure
through design/installation
0 to +55 °C
Installation in the living space
or boiler room (standard ambi-
ent conditions)
–20 to +85 °C
VITODENS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 200-wVitodens 222-w

Table of Contents