FRY TANK

WARNING: SHUT OFF THE GAS BEFORE
SERVICING.
WARNING: ALL GAS JOINTS DISTURBED
DURING SERVICING MUST BE CHECKED
FOR LEAKS.
CHECK WITH SOAP AND
WATER SOLUTION (BUBBLES). DO NOT
USE AN OPEN FLAME.
1. Disconnect fryer from main gas supply.
2. Remove baskets, fryer basket hanger and
crumb screen.
3. Drain oil from tank.
4. Remove heat shield as outlined under
Covers and Panels.
5. Remove screws holding fryer tank
(Figure 17).
Figure 17
6. Remove burners as outlined under
Burners.
7. Remove the manifold bracket from the
tank assembly by removing the (4) bolts
(Figure 18).
8. Remove thermostat and high limit as
outlined under Thermostat and High Limit.
9. Remove the screw securing the Pilot/
Thermopile Bracket Assembly (Figure 19).
10. Lift the fry tank up and out of cabinet.
Carefully place the tank assembly on the
floor (this procedure requires two people).
11. Remove the tank ball drain valve
(Figure 18).
12. Reverse the procedure to install new tank.
— 11 —
EF SERIES GAS FRYERS
Figure 18
Figure 19
F35641 (02-05)