EF SERIES GAS FRYERS

COMBINATION VALVE

WARNING: SHUT OFF THE GAS BEFORE
SERVICING.
WARNING: ALL GAS JOINTS DISTURBED
DURING SERVICING MUST BE CHECKED
FOR LEAKS.
CHECK WITH SOAP AND
WATER SOLUTION (BUBBLES). DO NOT
USE AN OPEN FLAME.
1. Disconnect fryer from main gas supply.
2. Remove heat shield as outlined under
Covers and Panels. (Optional)
3. Remove right burner as outlined under
Burners.
4. Disconnect
wire
combination valve and mark for
reconnecting.
5. Disconnect pilot tubing from combination
valve (Figure 15).
Figure 15
F35641 (02-05)
leads
from
the
— 10 —
6. Disconnect combination valve union and
pressure fitting (Figure 16).
Figure 16
7. Remove the combination valve from the
fryer.
8. Remove all pipe fittings from the old
combination valve if the new valve is not
supplied with fittings.
9. Reverse procedure to install using original
pipe fittings.