Basket Lift Cam; Pump And Motor; Fry Tank Assembly - Vulcan-Hart GRC35 Service Manual

Gr series gas fryers with tridelta controls
Table of Contents

Advertisement

GR SERIES GAS FRYERS - REMOVAL AND REPLACEMENT OF PARTS

BASKET LIFT CAM

WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES. THERE MAY
BE MULTIPLE CIRCUITS. BE SURE
ALL CIRCUITS ARE DISCONNECTED.
1. Remove basket lift cover as outlined in "BASKET
LIFT COVERS" under "COVERS AND PANELS".
2. Remove nut securing lift bar to cam assembly.
3. Loosen cam set screw.
4. Remove screws securing cam to the crank arm
assembly.
5. Reverse procedure to install.

PUMP AND MOTOR

WARNING: DISCONNECT THE ELECTRICAL POWER
TO THE MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES. THERE MAY BE MULTIPLE
CIRCUITS. BE SURE ALL CIRCUITS ARE
DISCONNECTED.
1. Open both fryer cabinet doors above the filter tank
drawer.
2. Pull the filter drawer out, remove the filter tank
assembly and push the tank support arms back
underneath the fryer.
NOTE: The remaining steps are written for front removal
of the pump assembly. If access to the back of the fryer
is available, it may be easier to remove the pump from
the rear.
3. Remove burners from the right side fryer section
above filter tank drawer as outlined under "GAS
BURNERS".
4. Disconnect the electrical connection to the motor.
5. Separate the swivel hose connections at the pump.
NOTE: When viewed from pump end, the right side is
the intake port and the left side is the discharge port.
6. Remove motor mounting bolts.
7. Remove the motor and pump (pipe fittings attached)
from the fryer.
A. If replacing the pump and motor, remove the
existing pipe assemblies and reuse.
8. Reverse procedure to install.
NOTE: Ensure the rubber vibration pad or the grommets
are installed under the motor mounting plate.

FRY TANK ASSEMBLY

WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES. THERE MAY
BE MULTIPLE CIRCUITS. BE SURE
ALL CIRCUITS ARE DISCONNECTED.
WARNING: SHUT OFF THE GAS BEFORE SERVICING
THE UNIT.
WARNING: ALL GAS JOINTS DISTURBED DURING
SERVICING MUST BE CHECKED FOR LEAKS. CHECK
WITH A SOAP AND WATER SOLUTION (BUBBLES).
DO NOT USE AN OPEN FLAME.
1. Drain frying oil from fryer tank.
2. Disconnect the gas supply line to allow access to
fryer from all sides.
3. Remove fryer baskets, crumb screen and basket
hanger.
NOTE: If the fryer is equipped with automatic basket
lifts, remove "lift arms" from the support rods before fry
tank removal.
NOTE: If the fryer is a battery section, remove grease
strip and split the silicone seal between the fryer section
tanks with a utility knife.
4. Remove the control panel as outlined in "CONTROL
PANEL" under "COVERS AND PANELS".
– 17 –
F-25114 Rev.A (07-03)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents