Thermopile - Vulcan-Hart EF3 ML-52099 Service Manual

Ef series gas fryers
Hide thumbs Also See for EF3 ML-52099:
Table of Contents

Advertisement

EF SERIES GAS FRYERS
8. Pull the high limit bulb through the
underside of the fry tank and remove the
high limit.
9. Reverse the procedure to install. When
installing the new high limit assembly, do
not kink the high limit capillary. Wrap
threads of packing nut with Teflon tape to
prevent leakage.

THERMOPILE

WARNING: SHUT OFF THE GAS BEFORE
SERVICING.
WARNING: ALL GAS JOINTS DISTURBED
DURING SERVICING MUST BE CHECKED
FOR LEAKS.
CHECK WITH SOAP AND
WATER SOLUTION (BUBBLES). DO NOT
USE AN OPEN FLAME.
1. Remove the screw securing the Pilot/
Thermopile Assembly Bracket to the tank
front. Lower the assembly away from the
tank (Figure 12).
2. Disconnect thermopile lead wires as
outlined under High Limit.
F35641 (02-05)
— 8 —
Figure 12

Hide quick links: