7
SOFTWARE FEATURES
Readable Codes
Code selection
Headers and Terminators
Operating modes
Configuration modes
Parameter storage
ENVIRONMENTAL FEATURES
Operating temperature
Storage temperature
Humidity
Ambient light immunity
Vibration resistance:
EN 60068-2-6
2 hours on each axis
Shock resistance:
IEC 68-2-27 test EA
3 shocks on each axis
Protection class
PHYSICAL FEATURES
Mechanical dimensions
Weight
* sealed connectors required; use Harting RJ Industrial® Push Pull Ethernet connector for Ethernet
models.
74
Interleaved 2/5
Code 39 Standard
Codabar
Code 128
EAN 128
Code 93 (standard and full ASCII)
EAN/UPC (including Add-on 2 and Add-on 5)
Up to 10 codes during one reading phase
Up to 128-byte headers and 128-byte terminators
On Line, Serial On Line, Automatic, Test,
PackTrack™, Continuous
Genius™ utility program
Non-volatile internal FLASH
0° to +50 °C (+32° to +122 °F)
-20° to +70 °C (-4° to +158 °F)
90% non condensing
Frequency range from 5 to 150 Hz;
Constant displacement 3 mm pk-pk from 5 to 9 Hz;
Constant acceleration 0.5 g from 9 to 150 Hz
VAC models
IP54*
470 x 300 x 141 mm (18.50 x 11.81 x 5.55 in)
about 11 kg (24 lbs. 3 oz)
20000 lux
30 g; 11 ms
VDC models
IP64*
DX8200A