DX8200A
2

Network Termination

When building a Lonworks system the network must be properly terminated by positioning
the BTK-8102 Lonworks terminator in the DX8200A master reader and the BTK-8100
Lonworks bus return in the last DX8200A slave reader.
The BTK-8100 bus return provides a connector to be inserted in the Lonworks 17-pin female
connector of the last slave reader in the network; while the BTK-8102 Lonworks terminator
provides a different connector to be inserted in the Lonworks 17-pin male connector of the
master reader:
DX8200A Master
DX8200A Last Slave
BTK-8100
BTK-8102
CAB-810X
Network
CAB-810X
Figure 17 - BTK-8102 and BTK-8100
Two cables are also provided as accessories to terminate and power the network: CAB-8605
and CAB-8305.
CAB-8605 is a power and Lonworks termination cable to be used for connecting the
DX8200A master to an external power unit within the network; while CAB-8305 is a power
and bus return cable to be used for connecting the last DX8200A slave to an external power
unit. These two cables must only be used for VDC models.
DX8200A Master
DX8200A Last Slave
Network
Power Unit
CAB-8305
CAB-8605
Figure 18 – CAB-8605 and CAB-8305
18