Datalogic DX8200A Reference Manual page 50

Hide thumbs Also See for DX8200A:
Table of Contents

Advertisement

2
The following image shows a system consisting of five readers where the external signals
(trigger, encoder, serial to host, etc.) are connected to the master through the C-BOX 100.
The system is powered by the PWR-240 where:
the master is connected through CAB-860X, which also provides bus termination
the last slave is connected through CAB-830X, which also provides bus return.
the master and all slaves are connected together through the CAB-810X cables
CAB810X
Slave 3
CAB810X
Slave 2
*
P.S. (Presence Sensor) connected to External Trigger/PS input.
**
C-BOX 100 modified to accept scanner power.
***
Encoder connected to IN2/ENC input.
Figure 39 – Small Synchronized Network with more than 2 Readers and Single Power Unit
34
CAB810X
Slave 4
CAB810X
Slave 1
CAB830X
CAB860X
C-BOX 100**
CAB601X
Master
Local Host
DX8200A
PWR-240
P.S.*
Encoder***