Use only halogen lamps as modeling light with the
maximal light output specified as follows:
Expert Pro series: 300W/G6.35/230V (Code 128)
Integra Pro series: 300W (G6.35/115V (Code 1280)
and 300W/G6.35/230V (Code 128), resp.
Make sure that the modeling lamp for units of the
Integra Pro series corresponds to the mains voltage.
Wait until the modeling lamp has cooled down, and
then remove the glass dome carefully from the unit by
pulling it out of the spring mechanism (see page 30)
and moving it straight away without touching modeling
lamp or flash tube (danger!). Handle halogen lamp with
care because of the high pressure inside. Pull out
halogen lamp and re-place the modeling lamp with a
new one.
Avoid touching the halogen lamp with your fingers;
this causes a higher risk of bursting of the halogen
lamp.

Replacement of flash tube

All unit types of Expert / INEGRA Pro are fitted with a
user-replaceable flash tube.
For replacement of flash tube switch the unit off,
separate it from the mains outlet and wait for at
least 15 minutes.
Then remove the glass dome from the head carefully
by pulling it out of the spring mechanism (see page 30)
and moving it straight away from the head without
touching modeling lamp or flash tube (danger!).
Handle flash tube with care because of the high
pressure inside.
Caution:
In case of a damaged flash tube glass the
electrodes of the tube must not be touched in any
case! In this case it is a must to use isolated pliers
for pulling out the flash tube!