Watch-Net And Watch-Net-All - Sun Microsystems Sun Fire V250 Administration Manual

Hide thumbs Also See for Sun Fire V250:
Table of Contents

Advertisement

show-devs Command
The show-devs command lists the hardware device paths for each device in the
firmware device tree.
ok show-devs
/i2c@1f,464000
/pci@1f,700000
/ppm@1e,0
/pci@1e,600000
/pci@1d,700000
/ppm@1c,0
/pci@1c,600000
/memory-controller@0,0
/SUNW,UltraSPARC-IIIi@0,0
/virtual-memory
/memory@m0,0
/aliases
/options
/openprom
/chosen
/packages
/i2c@1f,464000/idprom@0,50
/i2c@1f,464000/nvram@0,50
/pci@1e,600000/ide@d
/pci@1e,600000/usb@b
/pci@1e,600000/usb@a
...
show-devs Command Output (
CODE EXAMPLE 6-4

watch-net and watch-net-all

The watch-net diagnostics test monitors Ethernet packets on the primary network
interface. The watch-net-all diagnostics test monitors Ethernet packets on the
primary network interface and on any additional network interfaces connected to
the system board. Good packets received by the system are indicated by a period (.).
Errors such as the framing error and the cyclic redundancy check (CRC) error are
indicated with an X and an associated error description.
shows some sample output.
CODE EXAMPLE 6-4
truncated)
Chapter 6 Diagnostics
57