INSTALLATION

MOUNTING
The power amplifier can be installed in a standard 19-
inch equipment rack. It requires 3 units (5.25 inches)
for the XP 2000/2100, XP 3000/3100, and 2 units (3.5
inches) for the XP600/1000 of vertical rack space and
secures to the rack cabinet with four rack mount
screws and cup washers. In a rack, it is best to mount
units one above the other, with at least a unit of space
at least between two amplifiers. This provides efficient
airflow and support.
COOLING
Two variable-speed fans would start running as soon
as the power is being turned on. Before mounting your
amplifier, you should familiarize yourself with its cool-
ing requirements.
The air flows from the front to the back, so it is impor-
tant not to block the amplifier front air vents. If the
amplifier is rack-mounted, leave some space in front
of the rack to prevent heated air being drawn back
into the front-to-back airflow.
Airflow restrictions are the most common cause of
inadequate cooling. They may result from improper
mounting, bundles of power cords, clogged dust fil-
ters and closed rack doors. Mount the amplifier to
allow sufficient airflow out the front outlets to ensure
your amplifier work properly.
WIRING
The balanced XLR and TRS input connectors will ac-
cept the line-level output of most devices for ultimate
input convenience. The amplifier built-in XLR and TRS
connectors can be wired similarly for balanced or un-
balanced, floating or ground-referenced sources. The
output connector is a binding post with Speakon which
provides an easy connection when using
banana plugs, spade lugs or bare wires.
XP 600/1000/2000/2100/3000/3100
INPUT WIRING
OUTPUT WIRING
SPEAKON PIN OUT