10

Checking/adjusting the air pressure

.05
Fig. 10 - 04
10
Cleaning the air fi lter of the air-fi lter / lubricator
.06
Fig. 10 - 05
1
2
1
Care and maintenance
● Before operating the machine, always
check the air pressure on gauge 1.
2
● Gauge 1 must show a pressure of 6 bar.
● If necessary adjust to this reading.
● To do so, pull knob 2 upwards and turn
it so that the gauge shows a pressure of
6 bar.
To drain water bowl
● Water bowl 1 drains itself automatically
when the compressed-air hose is discon-
nected from the air-fi lter / lubricator
Cleaning fi lter
● Unscrew water bowl 1 an take out fi l-
ter 2.
● Clean fi lter 2 with compressed air or
isopropyl alkohol ( part No. 95-665 735-91 ).
● Screw in fi lter 2 and screw on water
bowl 1.
Switch the machine off!
Disconnect the air hose at the
air-fi lter / lubricator.