8
Mounting/connecting the start inhibitor
.05
Fig. 8 - 09
● For machines delivered without a table, the plate 1 from the accessories should be
mounted under the table top, so that the switch lug 2 is resting on plate 1 when the
sewing head is in an upright position.
● Loosen screws 3 and adjust switch 4 so that the switch lug 2 is free when the sewing
head is tilted back and pressed when the sewing head is upright.
● Connect plugs 5 and 6 to the switch 4.
Function check of the start inhibitor
● Switch the machine on at the main switch and tilt back the sewing head.
● The error message "Error 9" must appear on the control panel.
● If the message does not appear, check the setting of safety switch 4.
● After the sewing head has been returned to the upright position, the machine is
ready for operation again.
Installation and commissioning
1
3
6
2
4
5
25