Installation and commissioning
8
Fitting the tilt lock
.01.06
8
Connecting the plug-in connections and earth cables
.01.07
22
2
1
Fig. 8 - 06
Fig. 8 - 07
● Screw on tilt lock 1, provided in the ac-
cessories, using screw 2.
● Connect all plug connections as described
in the operations manual of the drive
● The following ground cables must be
attached in order to discharge static
electricity.
● Attach ground cables for machine, main
switch, control unit and motor to ground
point 1.
1
Do not operate the machine
without tilt lock 1!
Danger of crushing between
sewing head and table top!