8. SELECTING INSTALLATION LOCATION OF INDOOR UNIT

8.1 CONSIDERATIONS OF SELECTING INSTALLATION LOCATION
150 mm or more
120 mm
or more
Dimensions
120 mm
or more
1900 mm
or more
Back right
outlet location
Back left
outlet location
Right side
outlet location
Left side
outlet location
Select installation location which allows
minimum clearances for free air circulation
and easy accessibility for service and
maintenance.
• Select outlet location of piping from
indoor unit which allows easy access to
the ends of refrigerant piping lines to
facilitate refrigerant leak testing and to
facilitate service and maintenance.
• Select installation location so that the
wall hole required to pass the outlet
refrigerant piping lines, electrical cables
and condensate drain line from indoor
unit can be in one of the following Four
outlet locations
Avoid installation location which can lead to
excessive length of refrigerant piping lines
between indoor and outdoor units
Avoid installation location which can lead to
excessive height difference between indoor
and outdoor units