15. OUTDOOR UNIT INSTALLATION

15.1 PREPARATION STEPS BEFORE INSTALLATION
a.
Put packed unit as shown.
15.2 WALL INSTALLATION STEPS
Wall Support Parts
SR
Part Description
1
Right Side
2
Left Side
3
Back Angle
4
Front & Top Angle
5
Nut
6
Spring Washer
Steps of wall support assembly
(1) Fix back angle (item 3) with right side (item1) and left side (item 2)
by using 2 nuts (item 5) and 2 spring washers (item 6).
(2) Fix front angle (item 4) with right side (item 1) and left side (item 2)
by using 2 nuts (item 5) and 2 spring washers (item 6).
(3) Fix top angle (item 4) with right side (item 1) and left side (item 2)
by using 4 nuts (item 5) and 4 spring washers (item 6).
5
6
Detail A
A
Important Notes :
(1) Mount spring washer before mounting the nut.
(2) Tighten nut properly with torque wrench with tightening torque 5.7 Nm to have tight match.
(3) Be sure that the final appearance of assembled wall support to be leveled and same as figure.
Fix wall support into the wall
Put unit on the wall support.
Wall Installation
b. Lift unit from cardboard.
Qty
1
1
1
2
8
8
2
4
3
4
Outdoor
Unit
Wall
Support
21
c. Remove service door (item 2) by
1
Put outdoor unit on the floor support
Floor Installation
removing one screw (item 1).
Detach the cable clamp by
removing one screw.
2
1
2
4
3
4
Final Assembly
of wall support
Outdoor
Unit
Floor
Support
1

Advertisement

Table of Contents
loading

Table of Contents