XX. Adjusting the height
Note:
• The following "XX. Adjusting the height" to
"XXV. Adjusting the document stop position"
and "XXVII. Changing the stopper position"
shall be referenced only when installing d-Color
MF 552 plus/d-Color MF 452 plus.
• When installing the dual scan document feeder
DF-701 or reverse automatic document feeder
DF-624 to d-Color MF 362 plus/d-Color MF 282
plus/d-Color MF 222 plus, adjustments shall be
made according to the installation manual of
each option.
1. Check the clearance between the upper face of
scanner and the protrusion on the dual scan doc-
ument feeder side. (Three spots)
* There must be no clearance between the protru-
sion on the dual scan document feeder and the
upper face of scanner.
OK
NG
Protrusion
Y115290-3
Protrusion
A3CFIXC010DA
Protrusion
A3CEIXC003DB
2. If there is any clearance, adjust the height by
turning the adjustment screw on the right side
viewed from the back.
Clockwise: The rear side will move up.
Counterclockwise: The rear side will move down.
• If further adjustment is required, adjust the height
by using the adjustment screw on the left side
viewed from the back together.
Clockwise: The rear side will move up.
Counterclockwise: The rear side will move down.
XXI. Adjusting skew feed (Front side)
Note:
Perform this adjustment if necessary.
1. Close the dual scan document feeder.
2. Check how the edges of the chart are misaligned.
The amount of the deviation of the chart will be X.
X
Deviation in + (plus)
E-15
A2XKIXE027DA
X
Deviation in - (minus)
9J07IXC043DA