Introduction - Carrier 69NT40--541--200 TO 299 Operation And Service

Container refrigeration
Table of Contents

Advertisement

1.1 INTRODUCTION

The Carrier Transicold model 69NT40--541--200/299
series units are of lightweight aluminum frame
construction, designed to fit in the front of a container
and serve as the container's front wall.
They are one piece, self-contained, all electric units
which includes cooling and heating systems to provide
precise temperature control.
The units are suppled with a complete charge of
refrigerant R-134a and compressor lubricating oil and
are ready for operation upon installation. Forklift
pockets are provided for unit installation and removal.
The base unit operates on nominal 380/460 volt, 3
phase, 50/60 hertz power. An optional autotransformer
may be fitted to allow operation on nominal 190/230 , 3
phase, 50/60 hertz power. Power for the control system
is provided by a transformer which steps the supply
power down to 18 and 24 volts, single phase.
The controller is a Carrier Transicold Micro-Link 3
microprocessor.
The
automatically to select cooling, holding or heating as
required to maintain the desired set point temperature
within very close limits. The unit may also be equipped
with a mechanical or electronic temperature recorder.
The controller has a keypad and display for viewing or
changing operating parameters. The display is also
equipped with lights to indicate various modes of
operation.
1.2 CONFIGURATION IDENTIFICATION
Unit identification information is provided on a plate
located near the compressor. The plate provides the
unit model number, the unit serial number and the unit
parts identification number (PID). The model number
identifies the overall unit configuration while the PID
provides information on specific optional equipment,
factory provision to allow for field installation of optional
equipment and differences in detailed parts.
Configuration identification for the models covered
herein are provided in the Carrier Transicold Container
Identification
Matrix
at
www.container.carrier.com.
1.3 OPTION DESCRIPTION
Various options may be factory or field equipped to the
base unit. These options are listed in the tables and
described in the following subparagraphs.
SECTION 1
INTRODUCTION
controller
will
operate
the
Carrier
Web
site,
1.3.1 Battery
The refrigeration controller may be fitted with standard
replaceable batteries or a rechargeable battery pack.
1.3.2 Dehumidification
The unit may be fitted with a humidity sensor. This
sensor allows setting of a humidity set point in the
controller. In the dehumidification mode the controller
will operate to reduce internal container moisture level.
1.3.3 Control Box
The control box is composite material may be fitted with
a lockable door.
1.3.4 Temperature Readout
The unit may be fitted with suction and discharge
temperature sensors. The sensor readings may be
viewed on the controller display.
1.3.5 Pressure Readout
The unit may be fitted with suction and discharge
pressure gauges or suction and discharge transducers
or no pressure readout. The transducer readings may
be viewed on the controller display.
1.3.6 USDA
The unit may be supplied with fittings for additional
temperature probes which allow recording of USDA
Cold Treatment data by the integral DataCORDER
function of the Micro--Link refrigeration controller.
1.3.7 Interrogator
Units that use the DataCORDER function are fitted with
interrogator receptacles for connection of equipment to
download the recorded data. Two receptacles may be
fitted, one accessible from the front of the container and
the other mounted inside the container (with the USDA
receptacles).
1.3.8 Remote Monitoring
The unit may be fitted with a remote monitoring
receptacle. This item allows connection of remote
indicators for COOL, DEFROST and IN RANGE.
Unless otherwise indicated, the receptacle is mounted
at the control box location
1.3.9 Communications.
The unit may be fitted with a communications interface
module. The communications interface module is a
slave module which allows communication with a
master central monitoring station. The module will
respond to communication and return information over
the main power line. Refer to the ship master system
technical manual for further information.
1.3.10 Compressor
The unit is fitted with a single speed reciprocating
compressor.
1-1
T-317