Table 3-4 Controller Configuration Variables - Carrier 69NT40--541--200 TO 299 Operation And Service

Container refrigeration
Table of Contents

Advertisement

CONFIGURATION
NUMBER
CnF01
Bypass Valve Enable
CnF02
Evaporator Fan Speed
CnF03
Control Sensors
CnF04
Dehumidification Mode
CnF05
Reserved for future use
CnF06
Condenser Fan Speed Select
CnF07
Unit Selection, 20FT/ 40FT/45FT
CnF08
Single Phase/Three Phase Motor
CnF09
Refrigerant Selection
CnF10
Two Speed Compressor Logic
CnF11
Defrost "Off" Selection
CnF12
TXV/Solenoid Quench Valve
CnF13
Unloader
CnF14
Condenser Pressure Control (CPC)
CnF15
Discharge Temperature Sensor
CnF16
DataCORDER Present
CnF17
Discharge Pressure Sensor
CnF18
Heater
CnF19
Controlled Atmosphere
CnF20
Suction Pressure Sensor
CnF21
Autotransformer
CnF22
Economy Mode Option
CnF23
Defrost Interval Timer Save Option
CnF24
Advanced Pre-Trip Enhanced Test Series Option
CnF25
Pre-Trip Test Points/Results Recording Option
CnF26
Heat Lockout Change Option
CnF27
Suction Temperature Display Option
CnF28
Bulb Mode Option
CnF29
Arctic Mode
CnF30
Compressor Size
CnF31
Probe Check Option
CnF32
Single Evaporator Fan Option
CnF33
Snap Freeze Option
CnF34
Degree Celsius Lockout Option
CnF35
Humidification Mode
CnF36
SMV Type
CnF37
Electronic Temperature Recorder
CnF38
Quench Bypass Valve
CnF39
Expanded Current Limit Range
CnF40
Demand Defrost
CnF41
Lower DTT Setting
CnF42
Auto Pre--trip Start
CnF47
Fresh Air Vent Position Sensor
Note: Configuration numbers not listed are not used in this application. These items may appear when loading
configuration software to the controller but changes will not be recognized by the controller programming.

Table 3-4 Controller Configuration Variables

TITLE
3-13
DEFAULT
In
Out
dS (Dual)
SS (Single)
FOUr
duAL
On
OFF
----------
n/a
OFF (Single)
On (Variable)
40ft
20ft,45
1Ph
3Ph
r134a
r12, r22, bLEnd
Out (Single)
In (Dual)
noOFF
OFF
Out (TXV)
In (Solenoid)
Out
In
In
Out
Out
In
On (Yes)
OFF (No)
Out (No)
In (Yes)
Old (Low Watt)
nEW (High Watt)
Out (No)
In (Yes)
Out (No)
In (Yes)
Out
In
OFF
Std, Full
noSAv
SAv
Auto
Auto2, Auto 3
rSLtS
dAtA
Set to --10_C
Set to --5_C
Out
In
NOr
bULb
Out
In
41 CFM
37 CFM
Std
SPEC
2EF0
1EF0
OFF
SnAP
bOth
_F
OFF
On
1 (standard)
2, 3 (stepper)
rEtUR
SUPPL, bOth
Out
In
Out
In
Out
In
Out
In
Out
In
OFF
UPP, LOW
OPTION
T-317

Hide quick links: