Important Safety And Operating Information; Fireplace Safety; Clear Space - Heatilator I60 Owner's Manual

Table of Contents

Advertisement

3

Important Safety and Operating Information

A.

Fireplace Safety

Most problems are caused by improper installation and op-
eration of the fi replace. To provide reasonable fi re safety,
the following should be given serious consideration:
• The fi re should be supervised whenever the fi replace is
in use.
• An annual inspection should be performed on the
fi replace system.
• Install at least one smoke detector on each fl oor of your
home to ensure your safety.
• Install a conveniently located Class A fi re extinguisher
near the fi replace.
• Devise a practiced evacuation plan, consisting of at least
two escape routes.
• Devise a plan to deal with a chimney fi re:
- Evacuate.
- Notify the fi re department.
WARNING! Risk of Fire! Hearth & Home Technologies
disclaims any responsibility for, and the warranty and
agency listing will be voided by the following actions.
DO NOT:
• operate damaged fi replace
• modify fi replace
• overfi re
• install any unvented gas log set
• install any component not approved by Hearth & Home
Technologies
• install parts or components not Listed or approved
• operate the fireplace without fully assembling all
components
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
Heatilator • I60/I80 Owner's Manual • 4013-261 • Rev F • 07/21/14

1. Clear Space

Combustible materials must not be stored on the hearth
extension. Room furnishings such as drapes, curtains,
chairs or other combustibles must be at least 4 ft
(1219 mm) from the open front of the fi replace.
Combustible materials are materials made of or sur-
faced with any of the following materials:
- Wood
- Plant fi bers
- Plywood/OSB
- Any material that can ignite and burn, fl ame proofed
or not, plastered or un-plastered.
Non-combustible materials are materials which will not
ignite and burn, composed of any combination of the
following:
- Steel
- Brick
- Concrete
- Glass
WARNING! Risk of Fire! Keep combustible materials,
gasoline and other fl ammable vapors and liquids clear of
the fi replace.
DO NOT:
• store fl ammable materials close to the fi replace
• use gasoline, lantern fuel, kerosene, charcoal lighter
fl uid or similar liquids to start or "freshen up" a fi re in this
fi replace.
48 in. (1219 mm)
Clear Space
Front of Fireplace
12 in. (305 mm)
Clear Space
Sides of Fireplace
(from the FP opening)
Figure 3.1
Clear Space
- Compressed paper
- Plastic
- Drywall
- Iron
- Tile
- Slate
- Plasters
48 1/8 in. (1222 mm)
Clear Space
Bottom of Fireplace to
Lower Edge of Mantel
or Trim
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I80I80ctI80h

Table of Contents