VG4 Modular Camera Series
4.2

Pre-installation Check List

1.
2.
WARNING!
24 VAC Class 2 power supply only.
3.
4.
4.3

Dimensions

mm
inches
Figure 4.1 In-ceiling Dimensional Outline
4.4

Prepare Drywall Ceiling for Installation

1.
2.
Bosch Security Systems, Inc.
Determine the location and distance for the power supply box based on its voltage and
current consumption. See Section 5 Cable and Wire Standards, page 85 for specifications.
Install all rough wiring including: power, control, video, alarms I/O, relay I/O, and fiber
optic cabling.
A minimum of 216-mm (8 1/2-inch) of air space above the ceiling is required to install the
In-ceiling Mount.
If this AutoDome installation utilizes the AutoTracker feature, refer to
Section A Installation Notes for AutoTracker, page 101, before mounting the AutoDome.
176.8
DIA.
6.96
204.3
8.04
Choose the desired location to mount the dome.
Use the bracket Base Plate as a template or cut a 178 mm (7 in.) hole in the ceiling with
a drywall utility saw or Jig Saw. Proceed to Section 4.6 Wire the Interface Box, page 78, for
further instructions.
Installation Manual
Installing the In-Ceiling Mount | en
210.7
8.30
19.0
0.75
153.9
6.06
75
150.2
5.91
94.0
3.70
F.01U.162.025 | 6.0 | 2010.03