3.1.2

Description

Chapter 3 details how to install a VG4 AutoDome to a Roof Parapet or to a Pipe mount. Any
differences to the installation between these two mounting systems are noted. See Chapter 2
if you are installing a Pendant Arm to a Wall, Corner, or Mast (or pole) or see Chapter 4 if you
are mounting an In-ceiling AutoDome.
The VG4-A-9230 Series are stationary mounts intended for rooftop parapet vertical walls. They
are made of light weight aluminum with a corrosion-resistant finish and are used for all Bosch
AutoDome Modular Camera systems up to a rated load of 29 kg (64 lb). These mounts can be
fitted to the inside or outside of parapet walls and can swivel for ease of positioning and for
servicing the AutoDome.
3.1.3

Tools Required

3.2

Pre-installation Check List

1.
2.
NOTICE! Power and I/O cabling must be routed separately inside different permanently
earthed metal conduits.
3.
WARNING!
External interconnecting cables are to be installed in accordance to NEC, ANSI/NFPA70 (for
US application) and Canadian Electrical Code, Part I, CSA C22.1 (for CAN application) and in
accordance to local country codes for all other countries.
Branch circuit protection incorporating a 20 A, 2-pole Listed Circuit Breaker or Branch Rated
Fuses are required as part of the building installation. A readily accessible 2-pole disconnect
device with a contact separation of at least 3 mm must be incorporated.
4.
5.
Bosch Security Systems, Inc.
5 mm Allen wrench (supplied)
Small straight blade screwdrivers ~ 2.5 mm (0.1 in.) – 3.1 mm (1/8 in.)
Medium straight blade screwdriver
No. 1 and No. 2 Phillips screwdrivers
Socket wrench and 9/16 in. socket
Pipe Wrench
Barrel connector (if installing a fiber optic model)
Pin-in Torx tool (supplied) or a T25 pin-in Torx driver (for Pressurized Environmental
Housing)
Dial-indicator Torque Screwdriver (for Pressurized Environmental Housing)
Determine the location and distance for the power supply box based on its voltage and
current consumption. See Section 5 Cable and Wire Standards, page 88 for wiring
information and distances.
Use only UL listed liquid tight strain reliefs for conduits to the Power Supply Box to
ensure that water cannot enter the box. You must use water tight conduits and fittings to
meet NEMA 4 standards.
Install all rough wiring including: power, control, video coax, alarms I/O, relay I/O, and
fiber optic cabling. See Section 5 Cable and Wire Standards, page 88 for video and control
protocol methods.
Choose the appropriate VG4 AutoDome model (indoor or outdoor) for the environment in
which it will be used.
If this AutoDome installation utilizes the AutoTracker feature, refer to
Section A Installation Notes for AutoTracker, page 102, before mounting the AutoDome.
Installation Manual
Installing Roof Parapet and Pipe Mounts | en
F.01U.216.010 | 8.0 | 2011.02