Troubleshooting - Kenmore 625.34857 Owner's Manual

Deluxe demand water softeners
Table of Contents

Advertisement

SECTION 5
SERVICE TECH. INFORMATION
I
I
5A.
TROU B LES H OOTI N G
Keep this manual
with your water softener.
If repairs
are needed,
the service
technician
must have the informa-
tion on the following
8 pages.
For telephone
assistance,
call toll free,
1-800-426-9345.
WIRING
SCHEMATIC
Transformer
Turbine
Sensor
BACK OF TIMER
I
_I
/ [
24VAC
grn
o- ._.NC Position
brn
Switch
°NO
f
Sears WaterLine
for CustomerAssistance
1-800-426-9345
SALT
SIGNAL
LEV[L
LEV[L
0Ec.A00.0..0..
t°g
.oL2 _.Ec.A.GE.0w
Deluxe Demand Water Softener
with DualSegment E lectronic Display
)
ALWAYS
MAKE THESE
INITIAL
CHECKS
FIRST
1.
Does the time display
show
the correct
time of day?
°
°
°
°
--If
display
is blank,
check
power
source
to the soft-
ener.
--If time is flashing,
power
was off" f_)r over 24 hours. The
softener
resumes
normal
operation
but regenerations
occur
at the wrong
time.
--If an error
code (Example:
Err3) shows
in the face plate
display,
go to ALTOMATIC
ELECTRONIC
DIAGNOS-
TICS.
Plumbing
bypass
valve(s)
must
be
in Full
Service
position.
The
inlet
and
outlet
pipes
must
connect
to the
softener
inlet
and
outlet
respectively.
Is the transfk)rmer
plugged
into a "live", grounded
wall
outlet,
and the power
cable
fastened
securely?
The valve drain
hose must
be flee of kinks
and sharp
bends,
and not elevated
over
8 ft. above
the floor.
REMOVE THE TOP COVER AND SALT TANK COVER
6.
Is there salt in the storage tank?
"7. Is the
brine
tubing
connected?
(See
water
flow
diagrams).
8.
Is the brine valve float set right? (See page 23).
°
Press the SELECT button 2 times to display the hardness
setting.
Be sure
it is the con'ect
setting
for the
household's
water supply. (Make a hardness
test of the
raw water and compare with the hardness setting. Also
test a soft water sample to verify if a problem exists.)
Press the SELECT button
twice
more
to return
to
present time in the display.
If you do not find the problem
after making initial checks,
do the MA2VUAL INITIATED ELECTRONIC DIAGNOSTICS,
and the MANIYALADVANCE REGENERATION CHECK.