Kenmore 625.34857 Owner's Manual page 11

Deluxe demand water softeners
Table of Contents

Advertisement

SECTION 2
HOW YOUR WATER SOFTENER
WORKS
I
I
2A.
FACE PLATE TIMER FEATURES
OPTIONAL
SETTINGS-
CLEAN
FEATURE
MINUTES, MAXIMUM DAYS BETWEEN REGEN-
ERATIONS, and 12 / 24 HOUR TIME READINGS:
1. To set 1,2 or all 3 options,
press and hold SELECT
for 3 seconds.
Then press again until the CLEAN
TIME display shows.
cLEAN q"N1
TIME
I
default minutes
CLEAN
3
rain
TIME
example: time set to 3minutes
_CLEANfeature
minutes:
If you are using this
feature
(page 7), the length of the extra backwash
cycle automatically
sets to 7 minutes.
However,
you
can adjust this time from ] to ] 5 minutes in length. To
change this cycle time, use the UP button to increase
the time, or the DOWN button to shorten the time. If
no change
is desired,
continue
below.
2. Press
SELECT again
to
RECHARGE display.
RECHARGE
DAYl
default display
show
the
following
RECNARGE
LI °_l
example: set to 4 days maxi-
mum between regenerations
_Maximum
days
between
regenerations:
The
faceplate
timer automatically
controls
regeneration
frequency
(see page 14). This provides
the greatest
operating
efficiency,
and normally
the maximum
da!_sfeature
is not needed.
If you want to be certain
a regeneration
will occur within a number
of days,
use this feature. For example,
if your water supply
contains
iron
and
you
want
the
softener
to
regenerate
at least once every few clays to keep the
resin bed clean, set the display as typically shown
above. Setting is available from ] to ] 5 clays by using
the UP and DOWN buttons.
3. Press SELECT to show
the 12 HOUR display.
7_11 _
_12
or 24
hour
clock:
All
I L F,-_
time
displays
are
shown
in
,,ME
standard
clock time (1 to ] 2 PM;
and 1. to 12 AM) at the I2 hr
ctefault setting.
If military
time
_q_ll-
displays are desired,
set to 24 hr
,,ME
by pressing
the UP button.
4. Press SELECT to return the present time display.
WATER FLOW THROUGH
THE SOFTENER
If soft water is in use, the water
0
nn
t L
I_q
/
flow
bars
continually
scroll
WATERFLOW
no water flow
across
the
display.
The
bars
scroll slowly when water flow is
slow, and move faster as water
flow increases.
The flow bars do
not show when all faucets and
water using appliances
are off.
if°"
qnn_l
'"-'°/
:/
/
Flow bars scroll when
soft water is in use.
RECHARGE
TIME
REMAINING
and VALVE
POSITION
INDICATORS
One
of the valve
position
indica-
valve
recharge
position
time
tors (Serv, Fill, Brine,
Bkwsh,
indicators
re
ining
Rinse)
is ctisplayed
while
the
_I
ma
i, ,m i
softener
is
recharging
(See
_',ooI ULn_,_ I
-'._OTE on page 10 if the CLEAN
............
feature
is
ON).
RECHARGE
...... "...........
flashes in the display and, begin-
ning with BHne, the minutes of recharge
remaining
before
return
to service
appears
in place
of the
present
time. When the valve is moving from one
cycle
to another,
both
position
indicators
are
flashing.
PROGRAM
MEMORY
If electrical power to the softener
goes off, the time
display is blank but the face plate timer keeps the
correct
time for about
6 hours.
When
electrical
power comes on again, you have to reset the present
time only
if the display is flashing. The HARDNESS
and RECHARGE TIME never require resetting
unless
a change
is desired.
Even if the timer is incorrect
after a long power
outage, the softener
works as it should to keep your
water soft. However,
regenerations
may occur at the
wrong time of ctay until you reset the timer to the
correct time of clay.
ERROR CODE
An error code could appear
in
the face plate display if a prob-
lem occurs in the softener
elec-
tronics. If you see an error code
instead
of the present
time of
clay, please call you local Sears
Service Department
for service.
11