Kenmore 625.34857 Owner's Manual page 23

Deluxe demand water softeners
Table of Contents

Advertisement

SECTION 5
SERVICE TECH INFORMATION
I
I
5A.
TROU B LES H OOTI N G
MANUAL
ADVANCE
REGENERATION
CHECK
This
check
verifies
proper
operation
of the valve
motor,
brine
tank fill, brine
draw,
regeneration
flow
rates,
and other
controller
functions.
Always
make
the
initial
checks,
and
the
manual
initiated
diagnostics.
NOTES: The face plate display must show a steady
time (not flashing). If an Error code shows, first press
the SELECT button to enter the diagnostic
display.
1. Press the ON/OFF-HOLD
button and hold in for
3 seconds.
*RECHARGE and Fill begin to flash as
the softener
enters the fill cycle of regeneration.
When Fill is on steady,
remove
the brinewell
cover and, using a flashlight,
observe
fill water
entering
the tank.
*NOTE: If the CLEAN feature is set to ON, a cleaning
backwash
((,ZEAN and Bkwsb orRinse
flashes in the
display,
along with the minutes
of the clean cycle
remaining),
precedes
the recharge.
a.
If water does not enter the tank, look for an ob-
structed nozzle, venturi, fill flow plug, brine tub-
ing, or brine valve riser pipe.
CYCLE FLOW RATES (GALLONS PER MIN.)
FILL (flow to salt storage tank)
0.3 (1.1 liters)
BRINING
'_
.19 (.7 liters)
BRINE RINSE
I
.12 (.45 liters)
BACKWASH
(flow to drain)
2.0 (7.6 liters)
FAST RINSE
2.0 (7.6 liters)
2. After observing
fill, press the ON/OFF-HOLD
button to move the softener into brining. A slow
flow of water to the drain will begin. Verify brine
draw from the brine tank by shining a flashlight
into the brinewell
and observing
a noticeable
drop in the liquid level.
NOTE: Be sure a salt bridge is not preventing
water
with salt contact.
a.
If the softener
does
not draw
brine...
...nozzle
and/or
venturi
dirty or defective.
...nozzle
and venturi
not seated
properly
on
gasket.
...restricted
drain
(check
drain
fitting
and
hose).
...defective
nozzle
and venturi
seal.
...other
inner
valve
defect
(rotor
seal, rotor
&
disc, wave
washer,
etc.).
NOTE: If water system pressure
is low, an elevated
drain hose may cause back pressure,
stopping
brine
draw.
3.
Again press
ON/OFF-HOLD
to move
the soften-
er into backwash.
Ix)ok for a fast flow of
water
from
the drain
hose.
a.
An obstructed
flow indicates a plugged
top dis-
tributor,
backwash
flow plug, or drain hose.
.
.
Press
ON/OFF-HOLD
to move
the softener
into
fast rinse.
Again look for a fast drain
flow. Allow
the softener
to rinse for a few minutes
to flush out
any brine
that may remain
in the resin
tank from
the brining
cycle
test.
To return
the softener
to service,
press
ON/OFF-
HOLD.
_]
BRINE VALVE
lln
FREEBOARD
MEASUREMENT
(Distance from top of resin tank to top of
resin
r
FREEBOARD
7"-11"
Resin Tank
Resin Bed