SECTION 5
SERVICER'S
TECH. INFORMATION
5A.
TROUBLESHOOTING
KEEP THIS MANUAL WITH YOUR WATER SOFTENER. IF REPAIRS ARE NEEDED, THE SERVICE
TECHNICIAN
MUST HAVE THE INFORMATION ON THE FOLLOWING PAGES.
24VAC
WIRING SCHEMATIC
NC
tt
NO
N
DOWN
UP bumm
,/
ON_DFF - HOUDburn
SELECT imuan
ALWAYSMAKE THESE INmAL CHECKS FIRST
1.
Does the time display showthe correct Ume of day?.
...If display is blank, check power source to the
soRener.
...If time is flashing, powerwas off for over 6 hours.
The softener resumes normaloperation but regen-
erations occurat the wrong time.
...If an error code (Example: Err 03) shows in the face
plate display, go to AtJTO_C
ELECTRONIC
DIAGNOSTICS.
2.
Plumbing bypass valve(s) must be in Full Service
position.
3.
The inletand outletpipesmustconnect tothe softener
inlet and outletrespectively.
4.
Isthe transformerpluggedinto a qive", groundedwall
outlet, and the power cable fastened securely?
z
5. The valve drain hose mustbe free of Idnksand sharp
bends, and not elevated over 8 ft. above the floor.
REMOVE THE TOP COVER AND SALT TANK COVER
6. istheresaltin thestorage tank?
7.
Is the brine tubing connected? (See water flow
diagrams).
8.
Isthe brine valve float set right?(See page 22).
9,
Press the SELECT button 2 times to display the
hardnesssetting.Be sureitisthe correct settingfor the
households watersupply.(Make8 hardnesstest of the
rawwater and compere withthe hardnesssetUng. A lso
test a soft water sampie to verify if a problemexlsts.]l
Press SELECT 3 times to ratum the present time
display.
ffyou do notitnd theproblemaftermakinginitialchecks,do
the MANUAL INmATED ELECTRONIC DIAGNOSTICS,
and the MANUAL ADVANCE REGENERATION CHECK.
19