Thermostat Chart - Single Stage Heat Pump - Variable Speed Modulating Furnace - York TP9C Series Installation Manual

Modulating ecm residential gas furnaces
Hide thumbs Also See for TP9C Series:
Table of Contents

Advertisement

THERMOSTAT
THERMOSTAT
*BP21H50124
*BN21H00124
*DN22U00124
*DP21H40124
*DN21H00124
C
24 – Volt Common
24 – Volt Common
Y1
First Stage Compressor
First Stage Compressor
R
24 – Volt Hot
24 – Volt Hot
(Heat XFMR)
G
Fan
E
Emergency Heat
Emergency Heat
R
24 – Volt Hot
(Cool XFMR)
O/B
Reversing Valve
Reversing Valve
Energized in Cool
L
Malfunction Light
Malfunction Light
Y2
Second
Stage Compressor
Stage Compressor
AUX
Auxiliary Heat
Second Stage Heat
Thermostat Installer Setup
B/O Switch on Thermostat
1-System Type-must be set
must be in the O position
to 5 – 2 Heat/1 Heat Pump
Thermostat Installer Setup
2-Changeover Valve-must
be set to 0 – O/B terminal
Energized in Cooling
FIGURE 26: Thermostat Chart - Single Stage Heat Pump – Variable Speed Modulating Furnace
Johnson Controls Unitary Products
THERMOSTAT
*DP32H70124
C
C
24 – Volt Common
Y1
Y1
First Stage Compressor
R
R
24 – Volt Hot
G
G
Fan
Fan
E
E
Emergency Heat
W2
Third Stage Heat
O
O
Reversing Valve
Energized in Cool
L
L
Malfunction Light
Y2
Y2
Second
Second
Stage Compressor
W2
W1
Second Stage Aux. Heat
External Humidistat
(Optional)
Open on Humidity Rise
Step 1 of Thermostat
Installer / Configuration
Menu must be set to
Heat Pump 1
ID MODELS
TP9C
YP9C
CP9C
LP9C
MODULATING
FURNACE
MODULATING
FURNACE CONTROL
C
24 – Volt Common
Y1
Single
Stage Compressor
R
24 – Volt Hot
G
Fan
W
Modulating Heat
Y/Y2
Second or Full
Stage Compressor
O
Reversing Valve
Energized in Cool
LO COMP
Single Stage
Compressor (OUT)
HI COMP
Second Stage
Compressor (OUT)
DHUM
Dehumidification-
Open on Humidity Rise
Bonnet Sensor
(Optional)
Move HUMIDISTAT
jumper to "YES"
if humidistat is to be used.
1083292-UIM-A-0114
OD MODELS
YZB
YMB
H*3
SINGLE STAGE
HEAT PUMP
YORKGUARD VI
CONTROL
C
24 – Volt Common
Y1
Single
Stage Compressor
R
24 – Volt Hot
W1 OUT
First Stage Heat
W2 OUT
Second Stage Heat
Y2 OUT
Second
Stage Compressor
O
Reversing Valve
Energized in Cool
X/L
Malfunction Light
Y2
Second
Stage Compressor
W
Auxiliary Heat
BSG
Bonnet Sensor
BS
Bonnet Sensor
Change FFuel jumper
on the heat pump control
to "ON"
Change Hot Heat Pump
jumper on the heat
pump control to "ON" if
Hot Heat Pump
Operation is desired.
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents