York TP9C Series Installation Manual

York TP9C Series Installation Manual

Modulating ecm residential gas furnaces
Hide thumbs Also See for TP9C Series:
Table of Contents

Advertisement

INSTALLATION MANUAL
MODULATING ECM
RESIDENTIAL GAS FURNACES
MODELS: TP9C, YP9C, CP9C, and
LP9C Series
(Up to 98% AFUE Multi-position)
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
DUCTWORK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
GAS PIPING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
ELECTRICAL POWER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
VENTING CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . 21
COMBUSTION AIR AND VENT SYSTEM . . . . . . . . . . . . . . . . 27
Duct Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Combustible Floor Base Accessory . . . . . . . . . . . . . . . . . . . . . . . 6
Horizontal Application (Typical) . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Typical Attic Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Downflow Venting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Vertical Applications (Typical) . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Horizontal Right Application (Typical) . . . . . . . . . . . . . . . . . . . . . 8
Horizontal Left Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
PC Series Upflow Coil Installation . . . . . . . . . . . . . . . . . . . . . . . . 8
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Side Return Cutout Markings . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Gas Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Gas Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Electrical Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
and Non-Communicating AC . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Terminal Screw Wire Connection . . . . . . . . . . . . . . . . . . . . . . . 14
Variable Speed Modulating Furnace . . . . . . . . . . . . . . . . . . . . . 15
Variable Speed Modulating Furnace . . . . . . . . . . . . . . . . . . . . . 16
Unit Clearances to Combustibles . . . . . . . . . . . . . . . . . . . . . . . . 4
Coil Projection Dimensions - PC Series Coils . . . . . . . . . . . . . . . 8
Cabinet and Duct Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
High Altitude Orifices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Ratings & Physical / Electrical Data . . . . . . . . . . . . . . . . . . . . . 12
Maximum Equivalent Pipe Length . . . . . . . . . . . . . . . . . . . . . . . 28
Elbow Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Equivalent Length of Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
LIST OF SECTIONS
LIST OF FIGURES
. . . . . . . . . . . . . . . . . . . . . . . . . . 7
LIST OF TABLES
START-UP AND ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . 35
SAFETY CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
NORMAL OPERATION AND DIAGNOSTICS . . . . . . . . . . . . . 40
REPLACEMENT PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . 42
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
START UP SHEET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Variable Speed Modulating Furnace . . . . . . . . . . . . . . . . . . . . . 18
Variable Speed Modulating Furnace . . . . . . . . . . . . . . . . . . . . . 19
Variable Speed Modulating Furnace . . . . . . . . . . . . . . . . . . . . . 20
Upflow Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Downflow Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Horizontal Left Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Horizontal Right Configuration . . . . . . . . . . . . . . . . . . . . . . . . . 26
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Home Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Termination Configuration - 1 Pipe . . . . . . . . . . . . . . . . . . . . . . 31
Termination Configuration - 2 Pipe . . . . . . . . . . . . . . . . . . . . . . 31
Termination Configuration - 2 Pipe Basement . . . . . . . . . . . . . 31
Vent Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Vent Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Downward Venting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Ambient Combustion Air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Gas Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Furnace Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Size at Furnace (All Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Estimated Free Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Unconfined Space Minimum Area . . . . . . . . . . . . . . . . . . . . . . . 33
Free Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Gas Rate (CU FT/HR) at Full Input . . . . . . . . . . . . . . . . . . . . . . 36
Inlet Gas Pressure Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Nominal Manifold Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Blower Performance CFM - Any Position . . . . . . . . . . . . . . . . . 39
When paired with a
York heat pump
1083292-UIM-A-0114

Advertisement

Table of Contents
loading

Summary of Contents for York TP9C Series

  • Page 1: Table Of Contents

    INSTALLATION MANUAL MODULATING ECM RESIDENTIAL GAS FURNACES MODELS: TP9C, YP9C, CP9C, and LP9C Series When paired with a (Up to 98% AFUE Multi-position) York heat pump LIST OF SECTIONS SAFETY ......... . . 2 START-UP AND ADJUSTMENTS .
  • Page 2: Safety

    1083292-UIM-A-0114 The York YP9C is part of a “Hybrid Comfort System” when paired with a which has an external static pressure within the allowable range, as specified on the furnace rating plate. York Heat pump. When a furnace is installed so that supply ducts carry air circulated...
  • Page 3: Combustion Air Quality

    1083292-UIM-A-0114 CODES AND STANDARDS • Furnaces for upflow installation on combustible flooring shall not be installed directly on carpeting, tile or other combustible mate- Follow all national, local codes and standards in addition to this installa- rial other than wood flooring. tion manual.
  • Page 4: Unit Clearances To Combustibles

    1083292-UIM-A-0114 Where it will not interfere with proper air circulation in the confined FOR FURNACES INSTALLED IN THE COMMON- space. WEALTH OF MASSACHUSETTS ONLY Where the outdoor vent terminal will not be blocked or restricted. For all side wall horizontally vented gas fueled equipment installed in Refer to “VENT CLEARANCES”...
  • Page 5: Ductwork

    1083292-UIM-A-0114 SECTION II: DUCTWORK On all installations without a coil, a removable access panel is recom- mended in the outlet duct such that smoke or reflected light would be DUCTWORK GENERAL INFORMATION observable inside the casing to indicate the presence of leaks in the The duct system’s design and installation must: heat exchanger.
  • Page 6: Combustible Floor Base Accessory

    1083292-UIM-A-0114 LINE CONTACT ONLY PERMISSIBLE BETWEEN LINES FORMED BY THE SUPPLY AIR INTERSECTION OF FURNACE TOP AND TWO SIDES AND BUILDING JOISTS, STUDS OR FRAMING VENT (Maintain FURNACE required clearances to combustibles) FILTER RACK MUST BE A MINIMUM GAS PIPING WARM AIR PLENUM DISTANCE WITH 1”...
  • Page 7: Typical Suspended Furnace / Crawl Space Installation

    1083292-UIM-A-0114 COIL INSTALLATION On all installations without a coil, a removable access panel is rec- ommended in the outlet duct such that smoke or reflected light Support would be observable inside the casing to indicate the presence of leaks in the heat exchanger. This access cover shall be attached in such a manner as to prevent leaks.
  • Page 8: Horizontal Right Application (Typical)

    1083292-UIM-A-0114 FURNACE ASSEMBLY - MC SERIES COILS ONLY MC coils are supplied ready to be installed in a horizontal position. A horizontal pan is factory installed. MC coils should be installed in all hor- (Min) izontal applications with the horizontal drain pan side down. Mounting Plate Flexible Duct Collar...
  • Page 9: Filters

    1083292-UIM-A-0114 LEFT SIDE RIGHT SIDE FRONT Combustion Air Inlet Combustion Air Inlet Condensate Drain Gas Pipe Gas Pipe Condensate Drain (Downflow) Entry Entry (Downflow) 2” Vent Electrical Electrical Connection Entry 2” Vent Entry Outlet Connection Condensate Outlet Drain Condensate 23” Drain Thermostat Wiring...
  • Page 10: Gas Piping

    1083292-UIM-A-0114 Horizontal Filters Main Inlet On/Off Regulator Pressure Switch Adjustment All filters and mounting provision must be field supplied. All installa- Outlet tions must have a filter installed. Pressure Any branch duct (rectangular or round duct) attached to the plenum must attach to the vertical plenum before the filter.
  • Page 11: Electrical Power

    1083292-UIM-A-0114 GAS CONVERSION FOR PROPANE (LP) Read across that row to the column for the elevation at your loca- tion. The number listed there is the orifice size that is proper for This furnace is constructed at the factory for natural gas-fired operation, your unit.
  • Page 12: Electrical Wiring

    1083292-UIM-A-0114 Table 6: Ratings & Physical / Electrical Data Input Output Nominal Air Temp. Rise Air Temp. Rise BTUH/ Max/Min Max/Min Airflow Max Input Min Input Cabinet/CFM °F °C °F °C /min 60B12 60/21 17.6/6.2 58/20 17.0/5.9 1200 34.0 40-70 22-39 20-50 11-28...
  • Page 13: Control Wiring

    1083292-UIM-A-0114 CONTROL WIRING In order to use this furnace in full communications (COMM) mode, it MUST be installed with the matching touch-screen Communicating This furnace can be connected to the wall thermostat and outdoor A/C Control (wall thermostat) and an outdoor air conditioner or heat pump or heat pump using either conventional low voltage (24 VAC) thermo- with a fully communicating control.
  • Page 14: Modulating Furnace With Communicating Ac Or Hp

    1083292-UIM-A-0114 Touch Screen Modulating Furnace Air Conditioner/Heat Pump MODULATING FURNACE NOTE Communicating control Communicating control Communicating control WIRE COMMUNICATING CONNECTOR CONTROL ENSURE ONLY ONE WIRE UNDER TERMINAL SCREW. TO CONNECT MORE THAN ONE WIRE: THERMOSTAT 1. CONNECT ONLY TERMINAL GND or C END OF 6”...
  • Page 15: Thermostat Chart - Single Stage Air Conditioner - Variable Speed Modulating Furnace

    1083292-UIM-A-0114 For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available online at www.upgnet.com in the Product Catalog Section. ID MODELS TP9C YP9C CP9C THERMOSTAT LP9C SINGLE STAGE MODULATING SINGLE STAGE *PP11C70224 FURNACE AIR CONDITIONER...
  • Page 16: Thermostat Chart - Two Stage Air Conditioner - Variable Speed Modulating Furnace

    1083292-UIM-A-0114 ID MODELS TP9C YP9C CP9C THERMOSTAT THERMOSTAT LP9C TWO STAGE MODULATING *DN22U00124 *PP32U70124 FURNACE CONDITIONER MODULATING FURNACE CONTROL 24 – Volt Common 24 – Volt Common 24 – Volt Common 24 – Volt Common Single First Stage Compressor First Stage Compressor...
  • Page 17: Thermostat Chart - Two Stage Air Conditioner With Single Stage Thermostat - Variable Speed Modulating Furnace

    1083292-UIM-A-0114 ID MODELS TP9C YP9C CP9C THERMOSTAT LP9C TWO STAGE MODULATING *PP11C70224 FURNACE CONDITIONER MODULATING FURNACE CONTROL 24 – Volt Common 24 – Volt Common Single Full Stage Compressor First Stage Compressor Stage Compressor 24 – Volt Hot 24 – Volt Hot 24 –...
  • Page 18: Thermostat Chart - Single Stage Heat Pump - Variable Speed Modulating Furnace

    1083292-UIM-A-0114 ID MODELS OD MODELS TP9C E*R* *RHS YP9C E*ZD CP9C E*B* *HGD THERMOSTAT THERMOSTAT THERMOSTAT LP9C *BP21H50124 *BN21H00124 MODULATING SINGLE STAGE *DN22U00124 *DP32H70124 *DP21H40124 FURNACE HEAT PUMP *DN21H00124 MODULATING DEMAND DEFROST FURNACE CONTROL CONTROL 24 – Volt Common 24 – Volt Common 24 –...
  • Page 19: Thermostat Chart - Single Stage Heat Pump - Variable Speed Modulating Furnace

    1083292-UIM-A-0114 ID MODELS OD MODELS TP9C YP9C CP9C THERMOSTAT THERMOSTAT THERMOSTAT LP9C *BP21H50124 *BN21H00124 MODULATING SINGLE STAGE *DN22U00124 *DP32H70124 *DP21H40124 FURNACE HEAT PUMP *DN21H00124 YORKGUARD VI MODULATING CONTROL FURNACE CONTROL 24 – Volt Common 24 – Volt Common 24 – Volt Common 24 –...
  • Page 20: Thermostat Chart - Two Stage Heat Pump - Variable Speed Modulating Furnace

    1083292-UIM-A-0114 ID MODELS OD MODELS TP9C YP9C CP9C THERMOSTAT THERMOSTAT LP9C *DN22H00124 MODULATING TWO STAGE *PP32U70124 *DP22U70124 FURNACE HEAT PUMP YORKGUARD VI MODULATING CONTROL FURNACE CONTROL 24 – Volt Common 24 – Volt Common 24 – Volt Common 24 – Volt Common...
  • Page 21: Condensate Piping And Furnace Venting Configuration

    1083292-UIM-A-0114 ACCESSORY CONNECTIONS TWINNING The furnace control will allow power-switching control of various acces- These furnaces are not to be twinned. If more than one furnace is sories. needed in an application, each furnace must have its own complete duct system and its own wall thermostat. ELECTRONIC AIR CLEANER CONNECTION SECTION VI: CONDENSATE PIPING AND Two 1/4”...
  • Page 22: Typical Condensate Drain, Vertical Installation

    1083292-UIM-A-0114 NOTICE A loop has been added to the pressure switch vacuum hose. How- ever, ensure that all pressure switch hoses are routed such that they prevent any condensate from entering the pressure switch. It is possible for condensation to form inside the combustion air (intake) pipe in the summer months if significant length of combus- tion air pipe passes through conditioned space.
  • Page 23: Upflow Configuration

    1083292-UIM-A-0114 FIGURE 29: Upflow Configuration Johnson Controls Unitary Products...
  • Page 24: Downflow Configuration

    1083292-UIM-A-0114 FIGURE 30: Downflow Configuration Johnson Controls Unitary Products...
  • Page 25: Horizontal Left Configuration

    1083292-UIM-A-0114 FIGURE 31: Horizontal Left Configuration Johnson Controls Unitary Products...
  • Page 26: Horizontal Right Configuration

    1083292-UIM-A-0114 FIGURE 32: Horizontal Right Configuration Johnson Controls Unitary Products...
  • Page 27: Combustion Air And Vent System

    1083292-UIM-A-0114 SECTION VII: COMBUSTION AIR AND COMBUSTION AIR/VENT PIPE SIZING VENT SYSTEM The size of pipe required will be determined by the furnace model, the COMBUSTION AIR AND VENT SAFETY total length of pipe required and the number of elbows required. Table 7 lists the maximum equivalent length of pipe allowed for each This Category IV, dual certified direct vent furnace is designed for resi- model of furnace.
  • Page 28: Maximum Equivalent Pipe Length

    1083292-UIM-A-0114 Table 7: Maximum Equivalent Pipe Length Elevation Sea level - 2000 Elevation 6001 - 7000 Model Input (BTUH) Pipe Size (in) Max. equivalent Length (ft) Model Input (BTUH) Pipe Size (in) Max. equivalent Length (ft) 60,000 60,000 60,000 60,000 60,000 60,000 80,000...
  • Page 29: Elbow Dimensions

    1083292-UIM-A-0114 TABLE 10: Combustion Air Intake and Vent Connection Size at Furnace (All Models) FURNACE VENT CONNECTION SIZES Furnace Input Intake Pipe Size 2” (5.1 cm) Vent Pipe Size 2” (5.1 cm) Furnace vent pipe connections are sized for 2” (51 mm). pipe. Any STANDARD ELBOW LONG (SWEEP) ELBOW pipe size change must be made outside the furnace casing in a ver-...
  • Page 30: Home Layout

    1083292-UIM-A-0114 VENT CLEARANCES VENT TERMINAL FIXED AIR SUPPLY CLOSED AREA WHERE TERMINAL IS NOT PERMITTED FIXED CLOSED OPERABLE FIGURE 34: Home Layout Direct Vent Terminal Clearances Canadian Installations US Installation A. Clearance above grade, veranda, porch, deck, or 12” (30.5 cm) 12”...
  • Page 31: Termination Configuration - 1 Pipe

    1083292-UIM-A-0114 VENT SYSTEM 12” vertical separation between combustion air This furnace is certified to be installed with one of two possible vent Maintain 12” minimum 12” minimum intake and vent. clearance above configurations. below overhang highest anticipated 12” minimum Horizontal vent system. This vent system can be installed com- snow level.
  • Page 32: Combustion Air Supply

    1083292-UIM-A-0114 This furnace is certified to be installed with one of three possible com- bustion air intake configurations. VENT OUTDOOR COMBUSTION AIR: This is a direct vent configuration where the combustion air is supplied through a PVC or ABS pipe that is connected to the PVC coupling attached to the furnace and is terminated in the same atmospheric zone as the vent.
  • Page 33: Combustion Airflow Path Through The Furnace Casing

    1083292-UIM-A-0114 The free area of a supply air opening shall be calculated by sub- Vent pipe clamps tracting the blockage area of all fixed louvers grilles or screens COMBUSTION AIR into outlet of from the gross area of the opening. drain coupling Apertures in a fixed louver, a grille, or screen shall have no dimen- sion smaller than 1/4”...
  • Page 34 1083292-UIM-A-0114 Air Supply Openings and Ducts 1 square in. per 3000 BTU per hour (6.45 cm per 0.879 kW) of the total input rating of all equipment located in the enclo- An opening may be used in lieu of a duct to provide to provide the outside air supply to an appliance unless otherwise permitted by sure.
  • Page 35: Start-Up And Adjustments

    1083292-UIM-A-0114 It is recommended that when the gas supply is first connected to the furnace, the ground union be loosened until the odor of gas is detected. 12” minimum When gas is detected, immediately tighten the union and check for gas between bottom leaks.
  • Page 36: Gas Rate (Cu Ft/Hr) At Full Input

    1083292-UIM-A-0114 Multiply cubic feet per hour by heating valve (BTU/ft ) to obtain NOTICE input. If clocked rate does not match the input rate from the unit nameplate. If orifice hole appears damaged or it is suspected to have been follow steps in next section to adjust the manifold pressure.
  • Page 37: Gas Valve

    1083292-UIM-A-0114 ADJUSTMENT OF MANIFOLD GAS PRESSURE Main Inlet On/Off Inlet and manifold gas pressure may be measured by connecting the Regulator Pressure Switch Adjustment “U” tube manometer to the gas valve with a piece of tubing. Follow the appropriate section in the instructions below. Refer to Figure 45 for the locations of the pressure ports on the gas valve.
  • Page 38: Furnace Control Board

    1083292-UIM-A-0114 ADJUSTMENT OF FAN CONTROL SETTINGS Tap B is the humid profile. This profile is best-suited for installations where the humidity is frequently very high during cooling season, such Cooling - The airflow delivered by the furnace during cooling operation as in the southern part of the country.
  • Page 39: Blower Performance Cfm - Any Position

    1083292-UIM-A-0114 Table 17: Blower Performance CFM - Any Position High / Low Speed Cooling CFM 060B12 080B12 Jumper Settings Hi Cool Lo Cool Hi Cool Lo Cool COOL Jumper ADJ Jumper 1305 1290 1100 1090 1065 1015 1000 1000 High / Low Speed Cooling CFM 080C16 100C16 Jumper Settings...
  • Page 40: Safety Controls

    1083292-UIM-A-0114 SECTION IX: SAFETY CONTROLS LIMIT CONTROLS CONTROL CIRCUIT FUSE Limit Switch - This furnace is equipped with a high temperature limit control mounted to the left side of the furnace vestibule panel. This limit A 3-amp fuse is provided on the control circuit board to protect the 24- switch will open and shut off gas to the burners if it detects excessive air volt transformer from overload caused by control circuit wiring errors.
  • Page 41: Troubleshooting

    1083292-UIM-A-0114 TROUBLESHOOTING Three Red Flashes - Pressure switch open with inducer pressure above pressure switch setpoint (switch is open when it should be The following visual checks should be made before troubleshooting: closed). Check pressure switch and pressure transducer. Check to see that the power to the furnace and the ignition control Four Red Flashes - High limit switch open or defective temperature module is ON.
  • Page 42: Replacement Parts List

    Click on the “Brand Links” button b. Click on the “Customer Service” button • You can contact us by mail. Just send a written request to: Johnson Controls Unitary Products Consumer Relations 5005 York Drive Norman, OK 73069 Johnson Controls Unitary Products...
  • Page 43: Wiring Diagram

    1083292-UIM-A-0114 SECTION XII: WIRING DIAGRAM Wiring Diagram -97+% Modulating Condensing Furnace with ECM Motor CAUTION PRECAUTION 115VAC NEUT. OUVREZ LES DISJONCTEURS AVANT OPEN ALL DISCONNECTS BEFORE 115VAC LINE DE PROCEDER AVEC LE SERVICE SERVICING THIS UNIT POWER FACTOR (NOT USED ON 1/2 HP MOTORS) CHOKE VALVE 120VAC...
  • Page 44 1083292-UIM-A-0114 NOTES Johnson Controls Unitary Products...
  • Page 45: Start Up Sheet

    1083292-UIM-A-0114 SECTION XIII: START UP SHEET 33" 97% - 98% AFUE Modulating Gas Furnace Start Up Sheet Proper furnace start up is critical to customer comfort and equipment longevity Start-Up Date Technician Performing Start-Up Installing Contractor Name Owner Information Name Address City State or Province...
  • Page 46 Explain thermostat use and programming (if applicable) to owner Additional Job Detail Subject to change without notice. Published in U.S.A. 1083292-UIM-A-0114 Copyright © 2014 by Johnson Controls, Inc. All rights reserved. Supersedes: 1031020-UIM-D-1013 York International Corp. 5005 York Drive Norman, OK 73069...

Table of Contents