Thermostat Chart - Two Stage Air Conditioner - Variable Speed Modulating Furnace - York TP9C Series Installation Manual

Modulating ecm residential gas furnaces
Hide thumbs Also See for TP9C Series:
Table of Contents

Advertisement

1083292-UIM-A-0114
THERMOSTAT
*DN22U00124
C
24 – Volt Common
Y1
First Stage Compressor
R
24 – Volt Hot
(Heat XFMR)
G
Fan
E/W1
First Stage Heat
W2
Second Stage Heat
R
24 – Volt Hot
(Cool XFMR)
Y2
Second Stage
Compressor
Connection of the "C"
terminal, 24-volt common
is optional when used with
batteries
Thermostat Installer Setup
1-System Type-must
be set to 8-1 Heat/2 Cool
Conventional
Thermostat Installer Setup
15-Compressor Protection
must be set to 5
FIGURE 23: Thermostat Chart - Two Stage Air Conditioner – Variable Speed Modulating Furnace
16
THERMOSTAT
*PP32U70124
C
24 – Volt Common
Y1
First Stage Compressor
R
24 – Volt Hot
(Heat XFMR)
G
Fan
E/W1
Emergency Heat
AUX
Auxiliary Heat
R
24 – Volt Hot
(Cool XFMR)
Y2
Second Stage
Compressor
External Humidistat
(Optional)
Open on Humidity Rise
Connection of the "C"
terminal, 24-volt common
is optional when used with
batteries
Thermostat Installer Setup
0170-System Type-must
be set to 10-1 Heat/2 Cool
Multistage Conventional
ID MODELS
TP9C
YP9C
CP9C
LP9C
MODULATING
FURNACE
MODULATING
FURNACE CONTROL
C
24 – Volt Common
Y1
Single
Stage Compressor
R
24 – Volt Hot
G
Fan
W
Modulating Heat
Y/Y2
Second or Full
Stage Compressor
O
Reversing Valve
Energized in Cool
LO COMP
Single Stage
Compressor (OUT)
HI COMP
Second Stage
Compressor (OUT)
DHUM
Dehumidification-
Open on Humidity Rise
Move HUMIDISTAT
jumper to "YES"
if humidistat is to be used.
Johnson Controls Unitary Products
TWO STAGE
AIR
CONDITIONER
C
24 – Volt Common
Y1
First Stage Compressor
R
24 – Volt Hot
Y2
Second Stage
Compressor

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents