Thermostat Chart - Single Stage Heat Pump - Variable Speed Modulating Furnace - York TP9C Series Installation Manual

Modulating ecm residential gas furnaces
Hide thumbs Also See for TP9C Series:
Table of Contents

Advertisement

1083292-UIM-A-0114
THERMOSTAT
THERMOSTAT
*BP21H50124
*BN21H00124
*DN22U00124
*DP21H40124
*DN21H00124
N/A
FIGURE 25: Thermostat Chart - Single Stage Heat Pump – Variable Speed Modulating Furnace
18
THERMOSTAT
*DP32H70124
C
24 – Volt Common
Y1
First Stage Compressor
R
24 – Volt Hot
G
Fan
E
Emergency Heat
W2
N/A
Third Stage Heat
O
Reversing Valve
Energized in Cool
L
Malfunction Light
Y2
Second Stage Compressor
W1
Second Stage Aux. Heat
External Humidistat
(Optional)
Open on Humidity Rise
Step 1 of Thermostat
Installer / Configuration
Menu must be set to
Heat Pump 1
Step 9 of Thermostat
Installer / Configuration
Menu must be set to
Pump OFF
ID MODELS
TP9C
YP9C
CP9C
LP9C
MODULATING
FURNACE
MODULATING
FURNACE CONTROL
C
24 – Volt Common
Y1
Single
Stage Compressor
R
24 – Volt Hot
G
Fan
W
Modulating Heat
Y/Y2
Second or Full
Stage Compressor
O
Reversing Valve
Energized in Cool
LO COMP
Single Stage
Compressor (OUT)
HI COMP
Second Stage
Compressor (OUT)
DHUM
Dehumidification-
Open on Humidity Rise
Move HUMIDISTAT
jumper to "YES"
if humidistat is to be used.
Johnson Controls Unitary Products
OD MODELS
E*R*
*RHS
E*ZD
HP*
E*B*
*HGD
SINGLE STAGE
HEAT PUMP
DEMAND DEFROST
CONTROL
C
24 – Volt Common
Y
Compressor
R
24 – Volt Hot
W1/66(out)
Heat
O
Reversing Valve
Energized in Cool
X/L
Malfunction Light
W
Auxiliary Heat

Hide quick links: