Installer Setting-Setting Disinfection Operation
Setting values, such as enable/disable and starting time about Disinfection operation are decided.
Note
• All values are in °C.
• Selection of °C or °F is based on
the value of Function Code 04.
Value
Note
Value #1
Enable/Disable of Disinfection
Operation(00:Disable,01:Enable)
Value #2
Starting Date(Sunday:1,
Monday:2,....,Saturday:7)
Starting Time in 24 hours (00~23)
Value #3
Water temperature
(Inside sanitary water tank)
Value #1 of
Function Code
27
Function Code 27
Value #2 of
Function Code 26
Default
Range
00
00~01
06
01~07
23
00~23
Temperature profile
of Disinfection operation
Value #2 of
Time
1
Keep pressing Function Setting
button for 3 seconds to enter
installer setting mode until
code displayed in timer segment.
2
Repeat pressing button to select
Function code 26.
3
Change the Value section by pressing right direction button.
Ex) setting Value as Value #1 = '01'
Value #2 = '05'
Value #3 = '03'
4
Set the Value #2 by pressing up, down button.
5
Move to Value #3 part by pressing right
direction button.
6
Change the Value #3 by pressing up,
down button.
7
If you finish the setting, press set / clear
button to save the setting.
8
Press
button to exit or system will
automatically exit after 25
seconds without any input.
Installation instruction
Value #1
Value #2
Value #3
Value #2 and #3 are shown
after selecting Value #1 as '1'
Owner's Manual 31