LG ThermaV Owner's Manual page 24

Air-to-water heat pump
Hide thumbs Also See for ThermaV:
Table of Contents

Advertisement

Installation instruction
Installer Setting-Setting Sanitary Tank Leaving Water Temperature for Sanitary Water Heating
Determine heating setting temperature range of water tank leaving water.
Following instruction shows how to change the range of setting temperature from 40 °C~50°C to 35°C~65°C.
Note
• All values are in °C.
• Selection of °C or °F is based on the
value of Function Code 04.
24 Air-to-Water Heat Pump Owner's Manual
1
Keep pressing Function Setting
button for 3 seconds to enter
installer setting mode until
code displayed in timer segment.
2
Repeat pressing button to select
Function code 15.
Value
Note
Value #1
Upper Limit of setting range
Value #2
Lower Limit of setting range
3
Set the Value #1 by pressing up, down button.
Ex) setting Value as Value #1 = '65'
Value #2 = '35'
4
Move to Value #2 part by pressing right
direction button.
5
Set the Value #2 by pressing up, down
button.
6
If you finish the setting, press set / clear
button to save the setting.
7
Press
button to exit or system will
automatically exit after 25 seconds
without any input.
Value #1 : Upper
Limit of setting range
Value #2 : Lower
Limit of setting range
Default
Range
50
50~80
40
30~40

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents