Setting the termination

You must set the termination of the data signal in each dome (or device) to on or off. Only two of the four
switches (3 and 4) on the DIP are used (Figure 14). Switches 1 and 2 are not used at this time, so it does not
matter whether they are set to on or off. MAIN (pin 3) is for the dome input and AUX (pin 4) is for an auxiliary
device output.
To set the termination, see Figure 14 and do the following:
1. Set the termination to on if the dome or device is the final receiver location for the data signal.
2. Set the termination to off if the data signal needs to loop out to other domes or devices.
Note:
The switches are set to On by default. You need to turn them Off if you are looping the data signal.
Figure 14. Termination switches
Auxiliary
Main